5700 STEP TOP
F. Masonry Chimney
1 in. (25mm) Clearance
With Firestop
Ceiling Joist
Thimble,
12 in. (305mm)
Of Brick
Floor
Protector
Figure 14.1
WARNING
Fire Risk.
Follow Chimney Connector Manufacturer's
Instructions for Proper Installation.
ONLY use connector:
•
Within the room, between appliance and ceiling or wall.
Connector shall NOT pass through:
•
Attic or roof space
•
Closet or similar concealed space
•
Floor or ceiling
Maintain minimum clearances to combustibles
14
Spark Arrestor Cap
Concrete Cap
Rafter
Combustible Wall
Sheathing
Outside Air Rear Vent
Fire Risk.
When lining air-cooled factory-built chimneys:.
•
Run chimney liner approved to UL 1777 Type HT
requirements (2100 degrees F)
•
Re-install original factory built chimney cap ONLY
•
DO NOT block cooling air openings in chimney
•
Blocking cooling air will overheat the chimney
7038-206E
Fireclay Flue Liner
With Air Space
Flashing
Eave
Outside Air
Termination Cap
Airtight
Cleanout Door
WARNING
August 3, 2015