D. Factory-Built Chimney
The chimney can be new or existing, and must meet the
following minimum requirements.
Must be a 6 inch (152mm) diameter (ID) high
temperature chimney listed to UL 10 HT (2100
or ULC S629M.
Must use components required by the manufacturer
for installation.
Must maintain clearances required by the manufacturer
for installation.
Refer to manufacturers instructions for installation.
NOTICE: In Canada when using a factory-built chim-
ney it must be safety listed, Type UL103 HT (2100
C] CLASS "A" or conforming to CAN/ULC-
o
[1149
S629M, STANDARD FOR 650
CHIMNEYS.
Listed Termination Cap
Roof Brace (if required)
Trim Collar on
Inside Wall
Chimney
Connector
Floor
Protector
Figure 35.1 - Factory-Built Exterior Chimney
February 5, 2010
o
o
F)
o
C FACTORY-BUILT
Storm Collar
Flashing
Listed Chimney
Insulated " T "
Wall Support
7038-159C
5700 Step Top Wood Stove Series ACC
WARNING! Risk of Fire!
Inspection of Chimney:
• Chimney must be in good condition and meets the
minimum standard of NFPA 211.
F)
• Factory-built chimney must be 6 inches (152mm)
UL103 HT.
WARNING! Risk of Asphyxiation!
DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY
FLUE SERVICING ANOTHER APPLIANCE OR TO ANY
AIR DISTRIBUTION DUCT OR SYSTEM.
This may allow flue gases to enter the house.
Listed Chimney
Ceiling Support
Chimney
Connector
Floor
Protector
Figure 35.2 - Factory-Built Interior Chimney
Listed Termination Cap
Storm Collar
Flashing