R
D. Factory-Built Chimney
The chimney can be new or existing, and must meet the
following minimum requirements.
•
Must be a 6 inch (152mm) diameter (ID) high
temperature chimney listed to UL 103 HT (2100
or ULC S629M.
•
Must use components required by the manufacturer
for installation.
•
Must maintain clearances required by the manufacturer
for installation.
•
Refer to manufacturers instructions for installation.
NOTICE: In Canada when using a factory-built chim-
ney it must be safety listed, Type UL103 HT (2100
o
[1149
C] CLASS "A" or conforming to CAN/ULC-S629,
o
STANDARD FOR 650
C FACTORY-BUILT CHIM-
NEYS.
Listed Termination Cap
Roof Brace (if required)
Trim Collar on
Inside Wall
Chimney
Connector
Floor
Protector
Figure 35.1 - Factory-Built Exterior Chimney
November 28, 2011
WARNING! Risk of Fire!
Inspection of Chimney:
• Chimney must be in good condition and meets the
o
F)
• Factory-built chimney must be 6 inches (152mm)
WARNING! Risk of Asphyxiation!
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE
SERVING ANOTHER APPLIANCE.
DO NOT CONNECT TO ANY AIR DISTRIBUTION
DUCT OR SYSTEM.
This may allow fl ue gases to enter the house.
o
F)
Storm Collar
Flashing
Listed Chimney
Insulated " T "
Wall Support
7038-159D
5700 Step Top Wood Stove Series ACC
minimum standard of NFPA 211.
UL103 HT.
Listed Termination Cap
Listed Chimney
Ceiling Support
Chimney
Connector
Floor
Protector
Figure 35.2 - Factory-Built Interior Chimney
Storm Collar
Flashing
Page 35