Clearances To Combustibles - Quadra-Fire 57ST-ACC Installation Manual

5700 step top wood stove series
Hide thumbs Also See for 57ST-ACC:
Table of Contents

Advertisement

5700 STEP TOP
B. Clearances to Combustibles (UL and ULC)
NOTE: A, C and F measurements
are to center of fl ue
INSTALLATION: Full Vertical or Horizontal with Vertical Rise
SINGLE WALL PIPE - A, B, C and D dimensions are based off of standard 18" stove pipe clearances to combustibles or unit certifi ed clerances, which-
ever is greater
SINGLE WALL PIPE
DOUBLE WALL PIPE - A, B, C and D dimensions are based off of certifi cation clearances. Stove pipe manufacture clearances MUSt be adhered to if
they exceed certifi ed unit clearances.
DOUBLE WALL PIPE
INSTALLATION - Horizontal with Minimum 2 Foot Vertical Off Stove Top
SINGLE WALL PIPE
DOUBLE WALL PIPE
INSTALLATION - 90° Elbow off top of stove through backwall
SINGLE WALL PIPE
DOUBLE WALL PIPE
INSTALLATION: ALCOVE - Six inch (6") [152] diameter listed DOUBLE WALL air insulated connector pipe with UL 103 HT listed factory-built Class "A"
chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor.) Maximum depth of Alcove shall be no more than 48" [1220]
with a minimum height of 48" [1220] to top of unit, and the referenced clearances. Canada must comply with CAN/ULC-S269 M87 for the 650° factory
built chimney
DOUBLE WALL PIPE
BACKWALL / SIDEWALL
A
B
C
D
CORNER INSTALLATION
E
F
E
F
NOTE: Clearances may only be reduced by means approved by the regulatory authority having jurisdiction
WARNING
Fire Risk.
Comply with all minimum clearances to
combustibles as specifi ed.
Failure to comply may cause house fi re.
8
A
B
15-1/2 [394]
10-1/2 [267]
12-1/2 [318]
7-1/2 [191]
12-1/2 [318]
7-1/2 [191]
12-1/2 [318]
7-1/2 [191]
12-1/2 [318]
7-1/2 [191]
12-1/2 [318]
7-1/2 [191]
13-1/2 [343]
8-1/2 [216]
ALCOVE SIDE VIEW
ALCOVE TOP VIEW
C
D
28-1/2 [724]
15 [381]
28-1/2 [724]
15 [381]
28-1/2 [724]
15 [381]
28-1/2 [724]
15 [381]
28-1/2 [724]
15 [381]
28-1/2 [724]
15 [381]
28-1/2 [724]
15 [381]
G
A
C
NOTE: Service Space
In order to replace the tube channel assembly a clearance
of 19 inches (483mm) is required on the right side of stove in
order to remove the tubes with the stove in place.
If space is not available, the stove will have to be discon-
nected from the chimney to proceed with the tube replace-
ment.
7038-206E
E
F
2 [51]
15 [381]
45 [1143]
2 [51]
15 [381]
45 [1143]
N/A
N/A
45 [1143]
N/A
N/A
45 [1143]
2 [51]
15 [381]
45 [1143]
2 [51]
15 [381]
45 [1143]
N/A
N/A
45 [1143]
G
STOVE TO
CEILING
CLEARANCE
* If H = N/A, follow Pipe Manufacturer's
clearances
G
H
N/A
N/A
18 [457]
13 [330]
18 [457]
13 [330]
N/A
*
H
August 3, 2015