Tested and
Portland
O-T L
Oregon USA
Listed by
C
US
OMNI-Test Laboratories, Inc.
Pedestal Model
If the information in these instruc-
tions is not followed exactly, a
fi re may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• Do not overfi re - If heater or chimney con-
nector glows, you are overfi ring. Overfi ring
will void your warranty.
• Comply with all minimum clearances to
combustibles as specifi ed. Failure to
comply may cause house fi re.
WARNING
Fire Risk.
For use with solid wood fuel only.
Other fuels may overfi re and generate
poisonous gases (i.e. carbon monoxide).
www.quadrafi re.com
5700 STEP TOP WOOD STOVE SERIES
Advanced Combustion Control (ACC)
Owner's Manual
Installation and Operation
DO NOT DISCARD THIS MANUAL
• Read, understand and
Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING
Model:
57ST-ACC
CAUTION
follow these instructions
for safe installation and
operation.
Hot glass will cause burns.
Do not touch glass until it is cooled
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room as
fi replace.
Alert children and adults to hazards of high
temperatures.
High temperatures may ignite clothing or other
fl ammable materials.
Keep clothing, furniture, draperies and other fl ammable
materials away.
7038-159D
R
Leg Model
• Leave this manual with
party responsible for
use and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are
hot during operation AND
cool down.
Installation and service of this appliance should
be performed by qualifi ed personnel. Hearth &
Home Technologies recommends NFI certifi ed
professionals, or technicians supervised by an
NFI certifi ed professional.
November 28, 2011

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 57ST-ACC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Quadra-Fire 57ST-ACC

  • Page 1 O-T L Oregon USA Listed by Advanced Combustion Control (ACC) OMNI-Test Laboratories, Inc. Owner’s Manual Installation and Operation Model: 57ST-ACC Leg Model Pedestal Model CAUTION DO NOT DISCARD THIS MANUAL • Read, understand and • • Leave this manual with...
  • Page 2: Congratulations

    Hearth & Home Technologies welcomes you to our tradition of our stoves, inserts and fi replaces. And yet we are old- of excellence! In choosing a Quadra-Fire appliance, you fashioned when it comes to craftsmanship. Each unit is have our assurance of commitment to quality, durability, and meticulously fabricated and gold and nickel surfaces are performance.
  • Page 3: Table Of Contents

    5700 Step Top Wood Stove Series ACC Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided may result in death or serious injury. •...
  • Page 4: Warranty Policy

    5700 Step Top Wood Stove Series ACC Warranty Policy Page 4 7038-159D November 28, 2011...
  • Page 5 5700 Step Top Wood Stove Series ACC Page 5 November 28, 2011 7038-159D...
  • Page 6: Section 1: Listing And Code Approvals A

    Installation Codes in Canada. claims any responsibility for, and the warranty and agency listing will be voided by the above actions. The Quadra-Fire 5700 Wood Stove (ACC) meets the U.S. DO NOT: Environmental Protection Agency’s 1990 particulate emis- • Install or operate damaged appliance sion standards.
  • Page 7: Section 2: Operating Instructions I

    5700 Step Top Wood Stove Series ACC User Guide Operating Instructions WARNING HOT SURFACES! Glass and other surfaces are hot during operation AND cool down. Hot glass will cause burns. • DO NOT touch glass until it is cooled • NEVER allow children to touch glass •...
  • Page 8: Fire Safety

    5700 Step Top Wood Stove Series ACC D. Combustible/Non-combustible Materials B. Fire Safety To provide reasonable fi re safety, the following should be • Combustible Material given serious consideration: Material made of or surfaced with wood, compressed Install at least one smoke detector on each fl oor of paper, plant fi...
  • Page 9: Burning Process

    fl ames. placed on the burning of wood for home heating. During this stage of burning: In order to improve the situation, we at Quadra-Fire have • The fl ames must be maintained and not allowed to go out developed cleaner-burning wood appliances that surpass ensure the cleanest possible fi...
  • Page 10: Automatic Combustion Control (Acc)

    5700 Step Top Wood Stove Series ACC H. Automatic Combustion Control (ACC) Typically, when you build a fi re, you open the air controls fully and monitor the fi re to prevent it from going into an overfi re HIGH situation and/or burning your wood up too quickly before you Burn Rate shut down the air controls to the desired burn rate.
  • Page 11: Burn Rates And Operating Effi Ciency

    5700 Step Top Wood Stove Series ACC 5. Low Burn Rate* - Below 10,000 BTU/hr J. Burn Rates and Operating Effi ciency • Leave the Burn Rate Air Control at the bottom marker. For maximum operating effi ciency Leave the blower off until the burn is well established, i.e., 30 minutes.
  • Page 12: Correct Baffl E & Blanket Placement

    5700 Step Top Wood Stove Series ACC INCORRECT POSITIONS K. Correct Baffl e & Blanket Placement WARNING! Risk of Fire! Firebox damage due to improper baffl e placement is not covered by warranty. Operate the wood burning appliance with the baffl e in the correct position only. Not doing so could result in: •...
  • Page 13: Building A Fire

    5700 Step Top Wood Stove Series ACC L. Building A Fire 9. When ready to reload, It is best to fully open both the Burn Rate Air and Start-up Air Controls before reloading. WARNING! Risk of Fire! Keep combustible materials, gasoline and other fl...
  • Page 14: Wood Fuel

    5700 Step Top Wood Stove Series ACC M. Wood Fuel Moisture WARNING! Risk of Fire! WARNING! Risk of Fire! • Do NOT burn wet or green wood. • DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS • Wet, unseasoned wood can cause accumulation of SUCH AS GASOLINE, NAPHTHA OR ENGINE OIL.
  • Page 15: Blower Operating Instructions

    5700 Step Top Wood Stove Series ACC N. Blower Operating Instructions NOTE: If your Quadra-Fire wood appliance is equipped with an optional blower, you should follow these guidelines: Down (Closed) Up (Open) Burn Rate Air Control Figure 15.2 - Snap Disc Location...
  • Page 16: Opacity (Smoke)

    5700 Step Top Wood Stove Series ACC P. Opacity (Smoke) CAUTION! Odors and vapors released during initial Opacity is the measure of how cleanly your appliance is operation may be irritating to sensitive individuals. burning. Open windows for air circulation. Opacity is measured in percent: •...
  • Page 17: Section 3: Maintenance And Service

    5700 Step Top Wood Stove Series ACC Maintenance and Service A. Ash Removal System Operating and Cleaning • Frequency: As Necessary • By: Homeowner CAUTION! Risk of Injury! Gloves are recommended as Tool to Remove there may be sharp edges. Cover The stove and ashes must be completely cooled down ARS Access...
  • Page 18: Inspection/Cleaning

    5700 Step Top Wood Stove Series ACC D. Appliance Inspection - Routine C. Chimney and Chimney Connector Inspection/Cleaning • Frequency: Every 2 months at the same time the chim- ney and chimney connector are inspected. • Frequency: Every 2 months during heating season or as recommended by a certifi...
  • Page 19: Glass Cleaning

    5700 Step Top Wood Stove Series ACC F. Glass Cleaning 5. Install side bricks. Slide top of brick under clips on side of fi rebox and push the bottom of the brick until • Frequency: As desired it is fl ush with the side of the unit. •...
  • Page 20: Quick Reference Maintenance Guide

    5700 Step Top Wood Stove Series ACC I. Quick Reference Maintenance Guide BAFFLE & BLANKET PLACEMENT INSPECT FIREBRICKS & ASH COVER (AFTER EACH CLEANING) Step Top Models Only Baffl e and blanket placement is critical to heat out- Firebrick is designed to protect your fi rebox. Replace put, effi...
  • Page 21: Section 4: Troubleshooting Guide

    5700 Step Top Wood Stove Series ACC Troubleshooting Guide With proper installation, operation, and maintenance your woodstove will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist you or a qualifi ed service person in the diagnosis of a problem and the corrective action to be taken.
  • Page 22: Section 5: Service Parts Replacement D

    • Do NOT operate appliance with glass & door assembly removed. • Do NOT operate with glass cracked, broken or scratched. Quadra-Fire appliances are equipped with ceramic super heat-resistant glass, which can only be broken by impact or misuse. Figure 22.2...
  • Page 23: Baffl E Removal

    5700 Step Top Wood Stove Series ACC C. Baffl e Removal Baffle Board & Blanket even Remove all ash from the fi rebox, and extinguish all hot with front tube & resting on all embers before disposal into a metal container. tubes The baffl...
  • Page 24: Door Handle Assembly

    5700 Step Top Wood Stove Series ACC D. Door Handle Assembly 1. Install washer on door handle shaft. 2. Slide door handle through door. 3. Install second washer(s) as shown in Figure 24.1. 4. Install key in groove. 5. Align groove in latch cam with key; slide latch cam over shaft 6.
  • Page 25: Tube Channel Assembly Replacement

    5700 Step Top Wood Stove Series ACC E. Tube Channel Assembly Replacement 5. Slide the tube channel assembly all the way to left until Removing Tube Channel Assembly it is off the threads. Drop the right side down, then slide 1.
  • Page 26: Installer's Guide

    5700 Step Top Wood Stove Series ACC Installer’s Guide Getting Started Negative pressure results from the imbalance of air avail- A. Design and Installation Considerations able for the fi replace to operate properly. It can be stron- gest in lower levels of the house. NOTICE: Check building codes prior to installation.
  • Page 27: Locating Your Appliance And Chimney

    5700 Step Top Wood Stove Series ACC D. Locating Your Stove & Chimney NOTICE Location of the appliance and chimney will affect perfor- BEFORE INSTALLATION OF THIS APPLIANCE, CON- mance. As shown in Figure 27.1 the chimney should: TACT YOUR LOCAL MUNICIPAL BUILDING DEPART- MENT, FIRE DEPARTMENT, FIRE PREVENTION •...
  • Page 28: Rule

    5700 Step Top Wood Stove Series ACC F. 2-10-3 Rule These are safety requirements and are not meant to assure proper fl ue draft. Figure 28.1 10 ft. (305cm) or more Less than 10 ft. (305cm) Wall or Parapet 2 ft. (61cm)Minimum 3 ft.
  • Page 29: Tools And Supplies Needed

    5700 Step Top Wood Stove Series ACC G. Tools And Supplies Needed Pre-Burn Check List Before beginning the installation be sure the following tools and building supplies are available: Place the appliance in a location near the fi nal installation area and follow the procedures below: Reciprocating saw Framing material Open the appliance and remove all the parts and...
  • Page 30: Section 7: Dimensions And Clearances

    5700 Step Top Wood Stove Series ACC Dimensions and Clearances A. Appliance Dimensions NOTE: Flue Collar size is 6 inch (152mm) diameter (ID) 5700 Pedestal Model 5700 Leg Model 27.0 in. (686mm) 10-1/4 in. 13-1/2 in. (260mm) (343mm) 14-15/16 in. 17-1/8 in.
  • Page 31: Clearances To Combustibles (Ul And Ulc)

    5700 Step Top Wood Stove Series ACC B. Clearances to Combustibles (UL and ULC) NOTE: Clearances may only be reduced by means BACKWALL / SIDEWALL approved by the regulatory authority having jurisdiction ALCOVE SIDE VIEW 90° OFF TOP UP & OUT CEILING CLEARANCE CORNER INSTALLATION STOVE TO CEILING...
  • Page 32: Hearth Protection Requirements

    5700 Step Top Wood Stove Series ACC In Canada, similar fl oor protection must be provided 18 C. Hearth Protection Requirements inches (457mm) in front and 8 inches (203mm) from the FLOOR PROTECTION: sides and rear of the appliance. *See exception. •...
  • Page 33: Alternate Floor Protection

    5700 Step Top Wood Stove Series ACC D. Calculating Alternate Floor Protection Material Thermal Conductivity: k value The k value indicates the amount of heat (in BTU’s) that will fl ow in 1 hour throught 1 square foot of a uniform material 1 inch thick for each degree (F) of temperature difference from one side of the material to the other.
  • Page 34: Section 8: Venting And Chimney Systems

    5700 Step Top Wood Stove Series ACC Venting and Chimney Systems B. Chimney Systems A. Venting Systems • The chimney connector joins the stove to the chimney. The venting system consists of: • It must be a 6 inch (152mm) minimum diameter 24 gauge •...
  • Page 35: Factory-Built Chimney

    5700 Step Top Wood Stove Series ACC D. Factory-Built Chimney WARNING! Risk of Fire! The chimney can be new or existing, and must meet the Inspection of Chimney: following minimum requirements. • Chimney must be in good condition and meets the •...
  • Page 36: Masonry Chimney

    5700 Step Top Wood Stove Series ACC E. Masonry Chimney: Spark Arrestor Cap Fireclay Flue Liner Concrete Cap With Air Space Rafter Flashing 1 in. (25mm) Clearance With Firestop Ceiling Joist Eave Combustible Wall Thimble, 12 in. (305mm) Of Brick Sheathing Outside Air Rear Vent Outside Air...
  • Page 37: Masonry Chimney Liner

    5700 Step Top Wood Stove Series ACC F. Masonry Chimney Liner Wood Stud 2 in. For optimal performance, masonry chimneys used to vent (51mm) this appliance should be: Clearance from chimney wall Fireclay liner 5/8 in. 1. Lined with a 6 inch (152mm) stainless steel liner. (16mm) Minimum or Equivalent.
  • Page 38: Air Clearances

    5700 Step Top Wood Stove Series ACC G. Air Clearances • Masonry chimney clearance must meet NFPA 211 mini- ceiling mum requirement of 2 inches (51mm) to sheet metal 13.5” below ceiling to top supports and combustibles. of opening Wall or top of opening is a min.of •...
  • Page 39 5700 Step Top Wood Stove Series ACC Solid Pack Chimney with Metal Supports as a Thimble (Cont’d) Figure 39.1 WARNING! Risk of Fire! Do NOT pack insulation or other combustibles between spacers. • ALWAYS maintain specifi ed clearanes around venting and spacers and install spacers as specifi ed. Failure to keep insulation or other material away from vent pipe may cause a fi...
  • Page 40: Section 9: Appliance Set-Up

    5700 Step Top Wood Stove Series ACC Appliance Set-up WARNING! Risk of Fire and Asphyxiation! A. Outside Air Kit Installation A source of air (oxygen) is necessary in order for combustion Do not draw outside combustion air from: to take place. Whatever combustion air is consumed by the •...
  • Page 41: Pedestall Assembly And Ash Removal System Installation

    5700 Step Top Wood Stove Series ACC B. Pedestal Assembly and Ash Removal System (ARS) Installation NOTE: The Ash Removal System, must be installed fi rst before installing the pedestal. ARS Cover Included in Kit: Door assembly, door handle & magnet, ash drawer, fastener package.
  • Page 42 5700 Step Top Wood Stove Series ACC Pedestal and Ash Removal System (Cont’d) Installing Pedestal Assembly 1. Slide pedestal over adapter on bottom of stove and secure with screws supplied with the kit. Figure 42.1. 2. Line up holes in sides of pedestal with holes in adapter. 3.
  • Page 43: Leg Kit And Ash Removal System Installation

    5700 Step Top Wood Stove Series ACC C. Leg Kit and Ash Removal System (ARS) Installation Leg Brackets packaged inside firebox NOTE: The Ash Removal System, must be installed fi rst before installing the legs. Included in Kit: Door assembly, door handle & magnet, ash drawer, fastener package.
  • Page 44: Mobile Home Installation

    8. Floor protection requirements must be followed precisely. 9. Use silicone to create an effective vapor barrier at the You must use a Quadra-Fire Outside Air Kit Part location where the chimney or other component penetrates OAK-ACC for installation in a mobile home.
  • Page 45: Blower Installation (Optional)

    5700 Step Top Wood Stove Series ACC E. Blower Installation (Optional) F. Adjusting the Blower Speed Control The blower speed control for this unit is adjusted at the factory, 1. Align holes in mounting fl ange of blower with bolt holes in and normally does not require further adjustment.
  • Page 46: Section 10: Reference Materials

    5700 Step Top Wood Stove Series ACC Beginning Mfg Date: 4-10-09 Reference Materials Ending Mfg Date: A. Exploded View Part number list on following page. 04/11 Page 46 7038-159D November 28, 2011...
  • Page 47: Service Parts & Accessories

    7000-014 Cam Latch 430-1141 Black & Gold Component Pack (Includes Nickel Spring Handles 436-5350 Doors (1) 1/2” & (2) 1/4”, (2) Nickel Hinge Pins, Quadra-Fire Logo) Nickel Doors 436-5360 Door Handle Only 430-1131 Nut, Locking (For Door Handle) Pkg of 24 226-0100/24 Gasket, Glass Tape, 3/4 “...
  • Page 48 5700 Step Top Wood Stove Series ACC IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed Stocked in this manual may be ordered from an authorized dealer. at Depot ITEM DESCRIPTION...
  • Page 49 5700 Step Top Wood Stove Series ACC Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed Stocked in this manual may be ordered from an authorized dealer. at Depot ITEM DESCRIPTION...
  • Page 50 5700 Step Top Wood Stove Series ACC IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement Stocked parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer. at Depot ITEM DESCRIPTION...
  • Page 51: Service & Maintenance Log

    5700 Step Top Wood Stove Series ACC C. Service And Maintenance Log Date of Service Performed By Description of Service Page 51 November 28, 2011 7038-159D...