Chimney Systems

A. Locating Your Appliance & Chimney
Location of the appliance and chimney will affect
performance. As shown in Figure 10.1 the chimney should:
Install through the warm space enclosed by the building
envelope. This helps to produce more draft, especially
during lighting and die down of the fire.
Penetrate the highest part of the roof. This minimizes
the affects of wind turbulence and down drafts.
Location
Recommended
Windward
Figure 10.1
10
Recommended
Location
Marginal
Location
Not
Outside Air Kit Termination Cap
Consider the appliance location in order to avoid floor
and ceiling attic joists and rafters.
Locate termination cap away from trees, adjacent
structures, uneven roof lines and other obstructions.
Your local dealer is the expert in your geographic area and
can usually make suggestions or discover solutions that will
easily correct your flue problem.