Quadra-Fire 57ST-ACC-B Installation Manual

Quadra-Fire 57ST-ACC-B Installation Manual

5700 step top wood stove series

Advertisement

Quick Links

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
5700 STEP TOP WOOD STOVE SERIES
Automatic Combustion Control (ACC)
Model(s):
57ST-ACC-B
WARNING
Fire Risk.
For use with solid wood fuel only.
Other fuels may over fire and generate
poisonous gases (i.e. carbon monoxide).
Installation and service of this
appliance should be performed by
quali ed personnel. Hearth & Home
Technologies recommends HHT
Factory Trained or NFI certified
professionals.
1
Installation Manual
Installation & Appliance Set-Up
NOTICE: DO NOT DISCARD THIS MANUAL
Tested and
O-T L
Portland
Listed by
Oregon USA
C
US
OMNI-Test Laboratories, Inc.
If the information in these instruc-
tions is not followed exactly, a
fire could result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of
this or any other appliance.
• Do not over fire - If appliance or chimney
connector glows, you are over firing. Over
firing will void your warranty.
• Comply with all minimum clearances to
combustibles as specified. Failure to
comply may cause a house fire.
Hot glass will cause burns.
Do not touch glass until it is cooled
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room as
appliance.
Alert children and adults to hazards of high temperatures
High temperatures may ignite clothing or other
flammable materials.
Keep clothing, furniture, draperies and other flammable
materials away.
To obtain a French translation of this manual, please contact
your dealer or visit www.quadrafire.com
Pour obtenir une traduction française de ce manuel, s'il vous
plaît contacter votre revendeur ou visitez www.quadrafire.com
7038-206F
WARNING
WARNING
HOT SURFACES!
Glass and other surfaces are hot
during operation AND cool down.
NOTE
September 27, 2016

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire 57ST-ACC-B

  • Page 1 Model(s): • Do not store or use gasoline or other flam- 57ST-ACC-B mable vapors and liquids in the vicinity of this or any other appliance. • Do not over fire - If appliance or chimney connector glows, you are over firing.
  • Page 2: Table Of Contents

    H. Proper Draft ............15 NOTE: Hearth & Home Technologies, manufacturer of this appliance, reserves the right to alter its products, their specifications and/or price without notice. Quadra-Fire is a registered trademark of Hearth & Home Technologies. 7038-206F September 27, 2016...
  • Page 3: Important Safety Information

    Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. For assistance or additional information, consult a qualified The Quadra-Fire 5700 Series Wood Appliance meets the installer, service agency or your dealer. U.S. Environmental Protection Agency’s crib wood emission limits for wood appliances sold after May 15, 2015.
  • Page 4: Getting Started

    5700 STEP TOP ACC Install Guide Getting Started A. Design and Installation Considerations B. Fire Safety Consideration must be given to: To provide reasonable fire safety, the following should be given serious consideration: • Safety • Convenience Install at least one smoke detector on each floor of •...
  • Page 5: Negative Pressure

    5700 STEP TOP ACC C. Negative Pressure WARNING WARNING Fire Risk. Hearth & Home Technologies disclaims any Asphyxiation Risk. responsibility for, and the warranty will be voided by, the following actions: • Negative pressure can cause spillage of com- bustion fumes, soot and carbon monoxide. •...
  • Page 6: Install Checklist

    5700 STEP TOP ACC F. Install Checklist ATTENTION INSTALLER: Follow this Standard Work Checklist This standard work checklist is to be used by the installer in conjunction with, not instead of, the instructions contained in this installation manual. Customer: __________________________________________________________________________ Date Installed: __________________________________________________________________________ Lot/Address: __________________________________________________________________________ Location of Appliance:...
  • Page 7: Dimensions And Clearances

    5700 STEP TOP ACC Dimensions and Clearances A. Appliance Dimensions NOTE: Flue Collar size is 6 inch (152mm) diameter (ID) 5700 Step Top Pedestal Model 5700 Step Top Queen Anne Leg Model 27 (686mm) 10-1/4 13-1/2 (343mm) (260mm) 9-1/8 (232mm) 37-11/16 17-1/8 (435mm) 14-15/16...
  • Page 8 5700 STEP TOP ACC A. Appliance Dimensions (continued) NOTE: Flue Collar size is 6 inch (152mm) diameter (ID) 5700 Step Top Traditional Leg Model 33-7/8 (860mm) 24-7/16 (620mm) Figure 8.1 - Front View 25-15/16 (658mm) Figure 8.2 - Side View 7038-206F September 27, 2016...
  • Page 9: Hearth Protection Requirements

    5700 STEP TOP ACC In Canada, similar floor protection must be provided 18 inches B. Hearth Protection Requirements (457mm) in front and 8 inches (203mm) from the sides and rear of the appliance. Figure 9.2 *See exception. FLOOR PROTECTION: Floor protector must be non-combus- tible material, extending beneath appliance and to the front, *EXCEPTION: Non-combustible floor protector must extend sides and rear as indicated.
  • Page 10: Clearances To Combustibles

    5700 STEP TOP ACC C. Clearances to Combustibles MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS in inches (Millimeters) Note: A, C, and F Dimensions are to the center of the flue collar 5700 WOOD APPLIANCE INSTALLATION: FULL VERTICAL SINGLE WALL PIPE 15-1/2 (394) 10-1/2 (267) 28-1/2 (724) 15 (381)
  • Page 11: Chimney Systems

    5700 STEP TOP ACC Chimney Systems A. Locating Your Appliance & Chimney • Consider the appliance location in order to avoid floor and ceiling attic joists and rafters. Location of the appliance and chimney will affect perfor- mance. As shown in Figure 11.1 the chimney should: •...
  • Page 12: Chimney Termination Requirements

    5700 STEP TOP ACC B. Chimney Termination Requirements NOTICE: Locating the appliance in a basement or in a location of considerable air movement can cause intermittent Follow manufacturer’s instructions for clearance, securing smoke spillage from appliance. Do not locate appliance near flashing and terminating the chimney.
  • Page 13: Chimney Height/Rise And Run

    5700 STEP TOP ACC D. Chimney Height / Rise and Run Chimney: This product was designed for and tested on a 6 inch (152mm) The chimney can be new or existing, masonry or prefabricated chimney, 14 to 16 feet (420-480cm) high, (includes appliance and must meet the following minimum requirements and as height) measured from the base of the appliance.
  • Page 14 5700 STEP TOP ACC Listed Termination Cap ney connector. • Top of wall opening is a minimum of 13-1/2 inches Storm Collar (343mm) from ceiling or 4-1/2 inches (114mm) below minimum clearance specified by chimney connector Flashing manufacturer. NFPA 211 minimum vertical clearance of 18 inches (457mm) from chimney connector and ceiling or minimum recommended by chimney connector manu- facturer.
  • Page 15: Installing Chimney Components

    Maintain minimum clearances to combustibles Figure 15.2 H. Proper Draft To be sure that your Quadra-Fire insert burns properly, the chimney draft (static pressure) should be approximately -0.10 inches water column (W.C.) during a high burn and -0.04 inches W.C. during a low burn, measured 6 inches (152mm) above the top of the insert after one hour of operation at each burn setting.
  • Page 16: Appliance Set-Up

    5700 STEP TOP ACC Appliance Set-Up Pedestal Assembly and Ash Removal WARNING System (ARS) Installation Do NOT operate before fully assembling components. NOTE: The Ash Removal System, must be Burning your stove without a pedestal or leg kit installed first before installing the pedestal. attached: Included in Kit: ARS door assembly, ARS latch assembly, •...
  • Page 17 5700 STEP TOP ACC Ash Removal Spacer Figure 17.4 Figure 17.1 Ped Kit and Ash Removal System (Cont’d) Door latch with the Installing Ped Kit ash door rod locked 1. Follow Beginning installing the ARS system instructions provided in place on page 16.
  • Page 18: Access Cover Handle

    5700 STEP TOP ACC B. Access Cover Handle Ash Removel Insert Access Cover Handle handle into slot of ARS Cover to Drawer remove ARS Cover for cleaning ash out of firebox (Figure 18.4). Adapters Figure 18.1 Figure 18.4 Leg Kit and Ash Removal System (ARS) Installation NOTE: The Ash Removal System, must be...
  • Page 19 5700 STEP TOP ACC 6. Remove knock out from bottom of firebox by using a hammer (Figure 16.2 on page 16). 7. Install ash door assembly by sliding the rod at an angle Align top holes and repeat; secure into the slot on the left side (Figure 16.3 on page 16). 8.
  • Page 20: Traditional Leg Installation

    5700 STEP TOP ACC Traditional Leg Installation Caution! Included with Appliance: Leg brackets; inside firebox. CHECK BAFFLE BOARDS & CERAMIC BLANKET! • Verify that the baffle boards and ceramic blanket are Tools Required: 9/16 socket wrench and phillips screw driver. in their proper locations.
  • Page 21: Door Handle Assembly

    5700 STEP TOP ACC E. Door Handle Assembly WARNING INSTALL NEW DOOR HANDLE Asphyxiation Risk. Install washer on door handle shaft and slide door handle Length of outside air supply duct shall NOT exceed the through door. length of the vertical height of the exhaust flue. Install second washer(s) as shown and install key in groove.
  • Page 22: Blower (Optional)

    5700 STEP TOP ACC H. Adjusting The Blower Speed Control G. Blower (Optional) The blower speed control for this unit is adjusted at the factory, and normally does not require further adjustment. Tools Required: #2 Phillips head screwdriver With the appliance plugged in, turn the speed control 1.
  • Page 23: Mobile Home Installation

    5700 STEP TOP ACC Mobile Home Installation You must use a Quadra-Fire Outside Air Kit Part CAUTION OAK-ACC; which is available from you dealer, for installation in a mobile home. THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL AND CEILING/ROOF MUST BE MAINTAINED 1.
  • Page 24: Reference Materials

    5700 STEP TOP ACC Reference Materials Date of Service Performed By Description of Service 7038-206F September 27, 2016...
  • Page 25 5700 STEP TOP ACC Date of Service Performed By Description of Service September 27, 2016 7038-206F...
  • Page 26 5700 STEP TOP ACC Date of Service Performed By Description of Service 7038-206F September 27, 2016...
  • Page 27: Accessory List

    Upgrade, Door, Nickel UK-DRNL Accessory List Gasket, Manifold Pkg of 4 7038-168/4 Side view 57ST-ACC-B Service Parts Front looking into unit Beginning Manufacturing Date: Sept 2016 Ending Manufacturing Date: Active Ceramic blanket IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or...
  • Page 28: September

    Hearth & Home Technologies 1445 North Highway Colville, WA 99114 Division of HNI INDUSTRIES Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer log onto www.quadrafire.com CAUTION DO NOT DISCARD THIS MANUAL...

Table of Contents