(ACC)
R
If the information in these instructions
is not followed exactly, a fire could result
causing property damage, personal injury,
or death.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
Do not over fire - If appliance or chimney connector
glows, you are over firing. Over firing will void your
warranty.
Comply with all minimum clearances to combustibles
as specified. Failure to comply may cause house
fire.
Hot glass and appliance will cause burns.
Do not touch glass until it is cooled
Use leather gloves when reloading fuel
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room as
appliance.
Alert children and adults to hazards of high
temperatures
High temperatures may ignite clothing or other
flammable materials.
Keep clothing, furniture, draperies and other
flammable materials away.
Fire Risk.
For use with solid wood fuel only.
Other fuels may over fire and generate poisonous
gases (i.e. carbon monoxide).
7038-249C
WARNING
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
WARNING
07/21

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 57ST-ACC-AU and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Quadra-Fire 57ST-ACC-AU

  • Page 1 • Comply with all minimum clearances to combustibles as specified. Failure to comply may cause house MODEL: fire. 57ST-ACC-AU WARNING HOT SURFACES! Glass and other surfaces are hot during operation AND cool down. Hot glass and appliance will cause burns.
  • Page 2: Sample Of Serial Number / Safety Label

    ACC WOODFIRE COMPLIANCE LABEL This appliance has been TESTED TO AS/NZS4013 for Hardwood by Vipac Report # 30A-14-0102-TRP-361517-0 Date tested: April 2015 MODEL QUADRA-FIRE 5700 step top acc Freestanding Wood Stove OVERALL AVERAGE EFFICIENCY BURNING HARDWOOD WHEN TESTED IN ACCORDANCE WITH AS/NZS 4012: ............
  • Page 3: Table Of Contents

    K. Negative Pressure......14 L. Frequently Asked Questions ....14 Quadra-Fire is a registered trademark of Hearth & Home Technologies. 7038-249C...
  • Page 4: Warranty Policy

    5700 Step Top AU Wood Appliance B. Warranty Policy AUSTRALIAN WARRANTY INFORMATION Hearth & Home Technologies Inc (HHT) 352 Mountain House Road | Halifax, PA 17032 | (717-362-9080) HHT extends the following manufacturer’s warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer.
  • Page 5 5700 Step Top AU Wood Appliance OTHER RIGHTS The HHT manufacturer’s warranty is in addition to other rights and remedies that you may have under Australian law. Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage.
  • Page 6: Quick Start Guide

    5700 Step Top AU Wood Appliance C. Quick Start Guide NOTE: These are generic drawings and may not represent your specifi c model. 10 Pieces of Newspaper, 10-20 Pieces of Dry ITEMS NEEDED FOR FIRST FIRE: Kindling and Few Pieces of Dry Split Wood. OPEN AIR CONTROLS LOAD WOOD...
  • Page 7: Listing And Code Approvals

    NOTE: Hearth & Home Technologies, manufacturer of this appliance, reserves the right to alter its products, their specifications and/or price without notice. The Quadra-Fire 5700 Step Top Australian Wood Appliance is Hardwood Certified. Hardwood Particulate Emissions equaling 1.5 g/kg with a Space Heating Efficiency of 65%.
  • Page 8: Operating Instructions

    • Permit too much air to the fire In order to improve the situation, we at Quadra-Fire 1. Symptoms of Over-Firing have developed cleaner-burning wood appliances that Symptoms of over-firing may include one or more of the...
  • Page 9: Air Controls

    5700 Step Top AU Wood Appliance 3. Final Stage 3. Manual Timer Over-Ride The final stage of burning is the charcoal stage. This If you need to shut the ACC system off before it goes occurs when the flammable gases have been mostly through the cycle of shutting itself off;...
  • Page 10: Burn Rates And Operating Efficiency

    5700 Step Top AU Wood Appliance F. Burn Rates and Operating Efficiency WARNING For maximum operating efficiency Risk of Fire. This wood appliance has a manufacturer-set minimum When set on High Burn Rate and over-riding low burn rate that must not be altered. It is against federal the Automatic Combustion Control system an regulations to alter this setting or otherwise operate this over fire situation can occur and may result in a...
  • Page 11: Building A Fire

    5700 Step Top AU Wood Appliance G. Building A Fire NOTE: Before lighting your first fire in the appliance: • Build fire on brick firebox floor. • Do NOT use grates, andirons or other methods to NOTE: The special high temperature paint that your support fuel.
  • Page 12: Correct Baffle & Blanket Placement

    5700 Step Top AU Wood Appliance INCORRECT POSITIONS H. Correct Baffle & Blanket Placement WARNING Fire Risk Firebox damage due to improper baffle placement is not covered by warranty. Operate the wood burning appliance with the baffle in the correct position only. Not doing so could result in: •...
  • Page 13: Opacity (Smoke)

    5700 Step Top AU Wood Appliance I. Opacity (Smoke) J. Clear Space This is the measure of how cleanly your appliance is • Do NOT place combustible objects within 1.2m of the front of appliance (See Figure 13.1). burning. Opacity is measured in percent; 100% opacity is when an object is totally obscured by the smoke column •...
  • Page 14: Negative Pressure

    5700 Step Top AU Wood Appliance K. Negative Pressure WARNING Asphyxiation Risk. • Negative pressure can cause spillage of combustion fumes, soot and carbon monoxide. • Appliance needs to draft properly for safety. Negative pressure results from the imbalance of air To minimize the effects of negative air pressure: available for the appliance to operate properly.
  • Page 15: Maintenance And Service

    5700 Step Top AU Wood Appliance Maintenance and Service A. Quick Reference Maintenance Guide CAUTION! Start the first inspection after the first 2 months of use, or if performance changes, and adjust your schedule Allow the appliance to completely cool down before accordingly.
  • Page 16: Cleaning And Operating The Ash Removal System

    5700 Step Top AU Wood Appliance B. Cleaning and Operating the Ash Removal System WARNING Fire Risk. Make sure Ash Removal System door is sealed tight against the gasket. Air leakage may cause: • Over-fire condition • Flame and/or smoke spillage •...
  • Page 17: General Maintenance

    5700 Step Top AU Wood Appliance B. General Maintenance 2. Disposal of Ashes 1. Creosote (Chimney) Cleaning • Frequency: When ash is within 44mm of firebox lip • Frequency: Every 2 months during heating season or • By: Homeowner as recommended by a certified chimney sweep; more Ashes should be placed in a metal container with a tight frequently if chimney exceeds or is under 14-16 ft.
  • Page 18 5700 Step Top AU Wood Appliance 4. Glass Cleaning • Frequency: As desired • By: Homeowner Clean glass with a non-abrasive glass cleaner. Abrasive cleaners may scratch and cause glass to crack. If the deposits on the glass are not very heavy, normal glass cleaners work well.
  • Page 19: Troubleshooting Guide

    5700 Step Top AU Wood Appliance Troubleshooting Guide With proper installation, operation, and maintenance your wood appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist you or a qualified service person in the diagnosis of a problem and the corrective action to be taken.
  • Page 20: Service Part Replacement

    2. Install additional washer(s) as shown in Figure 20.1 3. Install key in groove. Quadra-Fire appliances are equipped with ceramic super 4. Align groove in latch cam with key; slide latch cam over heat-resistant glass, which can only be broken by impact or shaft misuse.
  • Page 21: Baffle Removal

    5700 Step Top AU Wood Appliance D. Baffle Removal Baffle Board even with front 1. Remove all ash from the firebox, and extinguish all hot tube & resting on all tubes embers before disposal into a metal container. 2. The baffle board has 2 pieces. With the ceramic blanket still in place, slide one baffle piece over the top of other one and pull out top piece through the door opening and then remove bottom baffle piece (Figure 21.1).
  • Page 22: Tube Channel Assembly Replacement

    5700 Step Top AU Wood Appliance E. Tube Channel Assembly Replacement NOTE: Soak the bolts with penetrating oil for at least 15 Removing Tube Channel Assembly minutes before trying to remove them. 1. Remove the right side shield by removing 3 Phillips 8.
  • Page 23: Reference Materials

    5700 Step Top AU Wood Appliance Reference Materials A. Service and Maintenance Log Date of Service Performed By Description of Service 7038-249C 07/21...
  • Page 24 5700 Step Top AU Wood Appliance Date of Service Performed By Description of Service 7038-249C 07/21...
  • Page 25 5700 Step Top AU Wood Appliance B. Exploded View 57ST-ACC-AU Service Parts Step Top Wood Stove Advanced Combustion Control Part number list on following page. 07/21 7038-249C 07/21...
  • Page 26 5700 Step Top AU Wood Appliance C. Service Parts 57ST-ACC-AU Service Parts IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor. . Provide model number and serial number when requesting service parts from your dealer or distributor.
  • Page 27 5700 Step Top AU Wood Appliance 57ST-ACC-AU Service Parts #17 Brick Set 17.5 17.8 17.8 17.4 17.1 17.8 17.1 17.8 17.1 17.1 17.2 17.1 17.1 17.1 17.7 17.1 17.6 17.1 17.1 17.6 17.7 17.1 17.6 17.6 17.3 17.1 17.4 IMPORTANT: THIS IS DATED INFORMATION .
  • Page 28 5700 Step Top AU Wood Appliance 57ST-ACC-AU Service Parts #28 Pedestal Assembly #29 Legs Assembly #27 Burn Rate Control Assembly 27.9 28.1 27.8 27.1 29.1 27.7 27.6 27.2 27.5 28.3 27.4 29.4 28.2 27.3 29.6 29.5 IMPORTANT: THIS IS DATED INFORMATION .
  • Page 29 5700 Step Top AU Wood Appliance D. Accesories 57ST-ACC-AU Service Parts IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor. . Provide model number and serial number when requesting service parts from your dealer or distributor.
  • Page 30 Hearth & Home Technologies 352 Mountain House Road Halifax, PA 17032 Division of HNI INDUSTRIES Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer log onto www.quadrafire.com CAUTION DO NOT DISCARD THIS MANUAL...

Table of Contents