Troubleshooting

If you think that something is wrong with the Alkaline Ionizer, check out the following points before requesting
repairs. If you decide that trouble has occurred, do NOT attempt to disassemble and repair the Alkaline Ionizer
yourself, but contact your dealer.
※ Sometimes suspected trouble is remedied by disconnecting the power plug and then re-connecting it.
■ What Do the Indicator Lamps Mean?
Symptom
The Generating Lamp does
not light up.
After using "Acidic Water"
the Water Quality Indicator
Lamp changes to "Purified
Water".
When I stop down the water
faucet while using "Acidic
Water", the Water Quality
Indicator Lamp suddenly
changes to "Purified Water".
The lamp changes to
"Alkaline" after I have used
"Acidic Water" or "Purified
Water".
The Cartridge Life Lamp
does not go on.
The Cartridge Replacement
Lamp does not go out even
after I replace the cartridge.
56
Cause and remedial action
Immediately after installing the unit or replacing the cartridge,
the Water Quality Indicator Lamp will blink for approximately
10 - 40 seconds while water is running through the unit.
Run water through the unit for approximately 3-4 minutes.
(This is to vent any air caught inside the cartridge.)
Did you leave the unit unused for 24 hours or more?
(The Water Quality Indicator Lamp is blinking and the buzzer
is beeping.)
Run water through the unit for approximately 15 seconds.
Is there sufficient water volume? (It requires approximately
1.2 L/min or more.)
Open up the water faucet to increase the amount of water.
Is the Cartridge Replacement Lamp lit up?
Replace the cartridge.
The unit is designed to automatically switch to "Purified
Water" when you close the water faucet after using "Acidic
Water".
This is not a malfunction.
This happens when you stop down the water faucet too far
or when the water flow diminishes due to fluctuations in the
water pressure, and the unit detects the lack of water running
through.
Press "Acidic Water" again, and gradually open the water
faucet until the Water Quality Indicator Lamp starts to
blink.
Is the "Alkaline priority" setting established?
To release Alkaline priority, while no water is running
through the main unit, press
heard (for about 3 seconds).
Is the water turned off?
This lamp will light up while water is running through the
unit and for approximately 30 seconds after the water is
turned off.
Did you forget to press the Reset button?
Close the water faucet and press the Reset button.
Did you press the Reset button while the power cord was
unplugged?
Plug in the power cord and press the Reset button.
until a long beep is
Reference
page
9
51
42
48 – 52
35
36
36
32
48
50 – 52