KitchenAid 2003 M Technical Education page 76

Built-in side-by-side refrigerator with variable capacity compressor
Table of Contents

Advertisement

COMPONENT
Stuck closed.
Inoperative.
Air Door
Reversed wiring.
Stuck open.
The indicator lights and alarm continue to
Alarm Reset
activate after service has been performed.
Both thermistors have failed.
Evaporator fan motor feedback signal lost.
Call Service
An over-temp condition occurs for 3 hrs or
Alarm
more.
Call service indicator only, no audible
alarm.
RC = Refrigerator Compartment
FC = Freezer Compartment
SYMPTOM
6-6
TEST PROCEDURE/ACTION
Run control diagnostics to check the air
door operation in step 6. A 12 volt square
wave is supplied to the air door in a series
of short pulses. It is not possible to obtain a
reliable voltage reading with a VOM. Check
for the air door binding with the cover.
Check the resistance of the air door motor
on the air door connector. The yellow wire
to the red wire should have a resistance
reading of 375 - 425 Ω. The white wire to
the blue wire should have a resistance
reading of RD 375 - 425 Ω.
Reversed wiring at the air door or at the
control board will cause the air door to oper-
ate exactly contrary to the needs of the
refrigerator. Verify the air door and cabinet
wiring is correct. DO NOT DISCONNECT
THE AIR DOOR WHILE THE CYCLE IS IN
PROGRESS.
Look for any kind of mechanical blockage.
Pressing the OVER TEMPERATURE RE-
SET will shut off the audio alarm, but this
does not affect the indicator light the first
time the OVER TEMPERATURE RESET is
pressed. The indicator light will shut off
once the OVER TEMPERATURE RESET is
pressed the second time. The audio alarm
will not sound again for the current condition
that caused the alarm until a new condition
occurs or until a Master Alarm Reset is per-
formed. A Master Alarm Reset can be per-
formed by pressing the POWER (ON/OFF)
twice or by turning the power to the refrig-
erator off and on again. The indicator light
will reactivate after the OVER TEMPERA-
TURE RESET is pressed if the condition
that caused the alarm is still present.
Call service is a visual and audio signal that
alerts the customer that the refrigerator
needs service but only for specific failure
modes, none of which are necessarily re-
lated to performance. Run control diagnos-
tics to check the operation of components.
If a particular component is not operating
properly, see that individual component's
section.
The alarm needs to be reset. Press the
OVER TEMPERATURE RESET to deacti-
vate the call service indicator (see "Alarm
Reset" section).

Hide quick links: