6.
To remove a microswitch:
a) Push the two locking tabs to unlock the
microswitch and slide the switch off the
pins.
b) Disconnect the wire connectors from
the switch terminals.
Microswitches
Locking Tab
7.
To remove the anti-run-on device (ARD):
a) Disconnect the 1/4" tubing from the
John Guest union at the bottom of the
refrigerator.
b) Remove the clip and tape from the 1/4"
tubing.
Tape
Clip
Water Reservoir Tubing
Clip
Microswitches
Locking Tab
John Guest Union
c) Push the ARD off the retaining bracket.
d) Remove the hex-head screw from the
ARD retaining bracket and remove the
bracket.
e) Feed the 1/4" tubing from the bottom
and pull the ARD and tubing out of the
door. NOTE: The tubing may be easier
to remove if you remove the tubing con-
duit from the bottom of the freezer door
(see below).
ARD
Bracket
Screw
4-33
ARD
Pull Tubing Out Of Door
Tubing Conduit