KitchenAid 2003 M Technical Education page 12

Built-in side-by-side refrigerator with variable capacity compressor
Table of Contents

Advertisement

Opening Dimensions
The solid soffit must be within 1" (2.5 cm)
maximum above the refrigerator. If the solid
soffit is higher than 1" (2.5 cm) or one is not
available, then the refrigerator must be braced
to prevent tipping during use.
If the anti-tip boards are needed, they must be
attached to the rear wall studs 80" to 90" (203
- 229 cm) above the floor (see "Install Anti-Tip
Boards" for more information).
NOTE: A clearance of 1/2" (1.3 cm) must be
maintained above the top grille in order for the
top grille to be removed.
1
/
"
2
(1.3 cm)
A grounded 3 prong electrical outlet should be
placed within 4" (10.2 cm) of the right side
cabinets or end panel.
The water shutoff should be located in the base
cabinet on either side of the refrigerator or
some other easily accessible area. If the water
shutoff valve is not in the cabinets, the plumb-
ing for the water line can come through the floor
or the back wall (see "Water Supply Require-
ments" for more information).
80" - 90"
(203-229 cm)
83
1
/
" (211.5 cm) min.
4
84
3
/
" (215 cm) max.
4
to bottom of solid soffit
3" (7.6 cm)
23
1
/
"
2
(60 cm) min.
Model
36 in. (91.4 cm)
42 in. (106.7 cm)
48 in. (121.9 cm)
2-2
4"
(10.2 cm)
77"
(196 cm)
A
Width
(see chart following)
6"
(15.2 cm)
11"
(28 cm)
6"
6"
(15.2 cm)
(15.2 cm)
Width A (as shown above)
35-1/2
in. (90.2 cm)
41-1/2
in. (105.4 cm)
47-1/2
in. (120.7 cm)