REPAIRS AT THE UNIT

Switch the unit off
Before all repair work: Unplug the power
plug from the outlet.
12.1

INLET VALVE BUTTON

1. Use a 17 mm spanner to screw out the inlet valve button.
2. Replace the wiper (1) and O-ring (2).
2
1
12.2

INLET VALVE

1. Place the enclosed 30 mm wrench on the trigger housing
(1).
2. Loosen the trigger housing (1) with light blows of a ham-
mer on the end of the wrench.
3. Screw out the trigger housing with the inlet valve (3) from
the paint section.
4. Pull of the clasp (4) using the enclosed screwdriver.
5. Place the enclosed 30 mm wrench on the inlet valve (3).
Turn out the inlet valve carefully.
6. Clean the valve seat (5) with a cleaning agent and brush
(ensure that no brush hairs are left behind).
7. Clean the seals (6, 7) and check for damage. Replace, if
necessary.
8. Check all the valve parts for damage. In case of visible
wear replace the inlet valve.
(OFF).
Installation
1. Insert the inlet valve (3) into the trigger housing (1) and
secure with the clasp (4). Ensure that the (black) seal (6) is
mounted in the trigger housing.
2. Screw the unit from the trigger housing and the inlet
valve into the paint section. The (white) seal (7) has to be
mounted in the paint section.
3. Tighten the trigger housing with the 30 mm wrench and
tighten with three light blows of the hammer on the end
of the wrench. (Corresponds to approx. 90 Nm tightening
torque).
1
6
4
3
5
7
GB
REPAIRS AT THE UNIT
53