REPAIRS AT THE UNIT

Switch the unit off.
Before all repair work: Unplug the power
plug from the outlet.
10.1

INLET VALVE

Disassembly
1. Place the enclosed 30 mm wrench on the housing (1).
2. Loosen the housing (1) with light blows of a hammer on
the end of the wrench.
3. Screw out the housing from the paint section.
4. Remove the ball (2) and spring (3).
5. Clean and check all parts for damage and replace if neces-
sary.
Installation
1. Replace the ball (2) and spring (3).
2. Screw the housing (1) into the pump section.
3. Tighten the housing with the 30 mm wrench and tighten
with three light blows of the hammer on the end of the
wrench. (Corresponds to approx. 65-70 Nm tightening
torque).
EN
REPAIRS AT THE UNIT
1
2
3
43