Never bend or curve a fiber when connecting it. After a fiber is installed well, the bend radius must
•
be not less than 40 mm (the minimum dynamic bend radius is 20 D, and the minimum static bend
radius is 10 D. D indicates the outer diameter of dust caps).
•
If the fiber has to pass through a metallic board hole, the hole must have a sleek and fully filleted
surface (the filleting radius must be not less than 2 mm). When passing through a metallic board
hole or bending along the acute side of mechanical parts, the fiber must wear jackets or cushions.
Insert and remove a plug with care. Never exert a fierce force to the fiber or plug; otherwise the
•
plug might be damaged or the fiber might be broken. Never pull, press or extrude the fiber fiercely.
For the allowed maximum tensile load and crush load, see
SFP+ cable
You can use SFP+ cables to connect SFP+ ports. The SFP+ cables available for the switch are 10 G SFP+
Cu cables, as shown in
Figure 51 SFP+ cable
(1) Connector
QSFP+ cable
You can use QSFP+ cables to connect QSFP+ ports.
Figure 52 QSFP+ cable
(1) Connector
Figure
51.
92
Table
57.
(2) Pull latch
(2) Pull latch