Grounding The Switch Through The Pe Wire Of An Ac Power Supply - HP 10504 Installation Manual

10500 switch series
Hide thumbs Also See for 10504:
Table of Contents

Advertisement

2.
Remove the grounding screws from the grounding holes at the rear of the chassis, as shown by
callout 2 in
3.
Fasten the grounding screws, which are attached with the dual-hole terminals of the grounding
cable, into the grounding holes of the chassis.
4.
Connect the ring terminal of the grounding cable to the grounding post of the grounding strip, and
fasten the grounding cable to the grounding strip with the hex nut.
Figure 15 Connecting the grounding cable to a grounding strip
(1) Attach the grounding screws with dual-hole terminals to the grounding holes
(2) Grounding sign
(5) Ring terminal
Grounding the switch through the PE wire of an AC power
supply
CAUTION:
Make sure the AC power supply uses a three-wire cable with a protection wire, and the PE wire of the AC
power supply is reliably grounded at the power distribution room or AC power supply transformer side.
In addition, make sure the PE connector on the switch is well connected to the PE wire of the AC power
supply.
If the switch is AC powered and no grounding strip is available at the installation site, you can ground
the switch through the PE wire of the AC power supply, as shown in
Figure
15.
(3) Grounding strip
(6) Hex nut
19
(4) Grounding post
Figure
16.