Switching fabric modules

CAUTION:
Do not install B-type switching fabric modules (LSU1FAB04B0, LSU1FAB08B0, and LSU1FAB12B0) and
D-type switching fabric modules (LSU1FAB04D0, LSU1FAB08D0, and LSU1FAB12D0) on the same
switch.
A-type and B-type switching fabric modules for the 10504 and 10508 switches can be used in the same
chassis, but the performance of B-type modules will be reduced to match the performance of A-type's.
The switching fabric modules provide a console port for HP Support to maintain the switches. Do not use
the console port if you have not been trained for that.
You can install up to four switching fabric modules in one switch chassis.
Table 24
shows the switching fabric module and chassis compatibility and
fabric module product code and model matrix.
Table 24 Switching fabric modules and chassis compatibility
Switching fabric model
LSU1FAB04A0
LSU1FAB04B0
LSU1FAB04D0
LSU1FAB08A0
LSU1FAB08B0
LSU1FAB08D0
LSU1FAB12B0
LSU1FAB12D0
Table 25 Switching fabric product code and model matrix
Switching fabric
model
LSU1FAB04A0
LSU1FAB04B0
LSU1FAB04D0
LSU1FAB08A0
LSU1FAB08B0
LSU1FAB08D0
LSU1FAB12B0
Compatible chassis
10504
10508, 10508-V
10512
Product
HP description
code
JC615A
HP 10504 400Gbps Type A Fabric Module
JC751A
HP 10504 880Gbps Type B Fabric Module
JG340A
HP 10504 880Gbps Type B Fabric TAA-compliant Module
JC752A
HP 10504 1.2Tbps Type D Fabric Module
JG341A
HP 10504 1.2Tbps Type D Fabric TAA-compliant Module
JC616A
HP 10508/10508-V 720Gbps Type A Fabric Module
JC753A
HP 10508/10508-V 1.04Tbps Type B Fabric Module
JG342A
HP 10508/10508-V 1.04Tbps Type B Fabric TAA-compliant Module
JC754A
HP 10508/10508-V 2.32Tbps Type D Fabric Module
JG343A
HP 10508/10508-V 2.32Tbps Type D Fabric TAA-compliant Module
JC749A
HP 10512 1.52Tbps Type B Fabric Module
JG338A
HP 10512 1.52Tbps Type B Fabric TAA-compliant Module
Minimum requirements
A minimum of two switching fabric modules are
required, and either slot 6 or slot 7 must have
one switching fabric module installed.
A minimum of two switching fabric modules are
required, and either slot 10 or slot 11 must have
one switching fabric module installed.
A minimum of two switching fabric modules are
required, and either slot 14 or slot 15 must have
one switching fabric module installed.
71
Table 25
shows the switching

Hide quick links: