Disassembly Procedures
!
Water Valve Removal
1. Disconnect power supply to unit.
2. Remove Top Cover.
3. Remove two screws each hot and 3 valve combo cold
valve.
Combo Cold Valve
4. Remove hose clamps and hoses.
NOTE: The hose circuitry is marked on the Dispenser
top.
Dispenser Removal
1. Disconnect power supply to unit.
2. Depress the release tab and slide drawer from
washer.
28
WARNING
Hot Valve
16025909 Rev. 0
To avoid risk of electrical shock, personal injury or
death; disconnect power to unit before servicing.
3. Remove Top Cover.
4. Remove clamps and hoses from dispenser.
Main
Pre
Bleach
Hot
Wash
NOTE: The hose circuitry is marked on the Dispenser
top.
5. Remove attachment screws and lift dipenser to
expose fill hose.
Main
Cold
©2005 Maytag Services