Maintenance work

6.3.2 Draining the water condensation

Water condensation may accumulate in the water separator of the pres-
sure controller.
Proper setting
Water condensation cannot rise up to the filter element (1).
Check the water level in the water separator on a daily basis.
Fig. 65: Draining the water condensation
(1) - Filter element
(2) - Water separator
Maintenance steps
1. Place the collection tray under the drain screw (3).
2. Unscrew the drain screw (3) completely.
3. Allow water to drain into the collection tray.
4. Tighten the drain screw (3).
Service Instructions 911-211 - 00.0 - 02/2015
WARNING
Risk of injury
Switch off the machine at the main switch and
disconnect it from the pneumatic network before
you drain the water from the water separator.
NOTICE
Machine damage due to too much water
Too much water can result in damage to the machine.
Check the water level every day and drain water, if necessary.
6
4
8
2
10
0
1
2
3
(3) - Drain screw