6.2 Thread suction device

Proper setting
The thread is sucked in properly. Check on a regular basis if the thread
suction device sucks in the thread properly without the walls of the hose
sticking together.
Setting steps
1. As soon as the thread is no longer sucked in properly, blow talcum

6.3 Pneumatic system

6.3.1 Setting operating pressure

Proper setting
The operating pressure is 6 bar.
Check the pressure on the pressure indicator every day. The pressure
cannot deviate by more than 1 bar.
Fig. 64: Setting operating pressure
Setting steps
1. Pull the pressure controller (1) up.
2. Turn the pressure controller until the pressure indicator (2) indicates
3. Push the pressure controller (1) down.
68
powder into the hose through the opening of the thread suction device.
NOTICE
Machine damage due to incorrect pressure
Incorrect pressure can result in damage to the machine. Make sure
that the machine is only used when the operating pressure is set
correctly.
1
6
4
8
2
10
2
0
(1) - Pressure controller
6 bar:
• clockwise: to increase pressure
• counterclockwise: to reduce pressure
(2) - Pressure indicator
Service Instructions 911-211 - 00.0 - 02/2015