Machine head
Adjusting the thread suction device
Proper setting
The thread suction device reliably sucks in the thread. Even though posi-
tioned closely to the swung-out needle thread advancing device, the
thread suction device does not interfere with the swivel motion performed
by the needle thread advancing device.
Fig. 49: Adjusting the thread suction device I
(16) - Angle bracket with screws
Setting steps
1. Depending on the clamping system used, adjust the position using the
screws on the corresponding angle bracket (16).
52