CLEAR DATA

• CLEAR DATA is used to clear data of various types.
A. DRAM CLEAR
• Clear all data in the memory file and free all memory to 100%, the user data are not
affected. But only clear DRAM data on PWB-P.
NOTE
Not include DRAM data on NIC.
B. SRAM CLEAR
• To clear the settings for the functions listed at the following and return the functions to
their default settings.
• The following items are cleared (initialization).
NOTES
• Before executing "SRAM CLEAR," be sure to record the setting values that are to
be initialized through "SRAM CLEAR."
• For the record of the setting values, it is a good idea to have reports and lists
printed.
☞ 22 PRINT REPORT
☞ 86 REPORT
• Some setting values are not included any of these reports or lists. Be sure to make
a note of them separately.
• After "SRAM CLEAR" has been executed, make necessary entries of data again
based on the setting values recorded.
MODE
MACHINE SETTING
ADMIN. MANEGE-
MENT
FAX REGISTRATION ONE TOUCH DIAL
TX OPERATION
UTILITY
MODE
RX OPERATION
COMM. SETTING
Initialized Items
BUZZAR VOLUM
REMOTE MONITOR
SPEED DIAL
GROUP DIAL
PROGRAM DIAL
BATCH TX
MAIL BOX
SCAN CONTRAST
RESOLUTION
DEFAULT TX
HEADER
MEMORY RX MODE
NO. of RINGS
REDUCTION RX
RX PRINT
RX MODE
FORWARD
FOOTER
SELECT TRAY
CLOSED NETWORK\
TONE/ PULSE
LINE MONITOR
PSTN/ PBX
Default
LOW
MACHINE STATUS LIST
LIMITED
None
None
ONE TOUCH LIST
None
SPEED DIAL LIST
None
KEY SETTING LIST
None
MACHINE STATUS LIST
None
None
0
MACHINE STATUS LIST
STD
MEM. TX
ON
OFF
MACHINE STATUS LIST
2
ON
MEMORY RX
AUTO RX
OFF
OFF
ENABLE
OFF
TONE
MACHINE STATUS LIST
LOW
PSTN
8. Service Mode
Report/ List
25
None
23
25
25
25
25
95