8. Service Mode
I.
FUSER TEMP. Ad (OHP)
Functions
• To set the fusing temperature when OHP transparencies are used.
Use
• When fusing failure occurs
Setting/Procedure • The default setting is "0".
<Temperature table for adjusting fusing temperature for OHP film>
For bizhub 162
Setting value
1
0
(default value)
-1
For bizhub 180 / bizhub 210
Setting value
1
0 (default value)
-1
62
"0"
Setting range : -1 to +1
Paper width
CD
251 mm or more
250 mm or less
251 mm or more
250 mm or less
251 mm or more
250 mm or less
Mode selected in Service's Choice
Mode 1
Fusing Heater Lamp temperature (main/sub)
Field Service Ver. 1.0 Apr. 2005
Mode selected in Service's Choice
Mode 1
Fusing Heater Lamp temperature
180 °C
165 °C
180 °C
155 °C
170 °C
145 °C
Mode 3
175 °C
165 °C
155 °C
Mode 3
175 °C
165 °C
165 °C
155 °C
155 °C
145 °C