8. Service Mode
G. FUSER TEMP. Ad (PLAIN)
Functions
• To set the temperature of the Fusing Roller for each type of paper, thereby mak-
Use
• When fusing failure occurs
• When the type of paper is changed
Setting/Procedure • The default setting is "0".
<Temperature table for adjusting fusing temperature for plain paper>
For bizhub 162
Setting value
251 mm or more
2
250 mm or less
251 mm or more
1
250 mm or less
251 mm or more
"0"
(default value)
250 mm or less
251 mm or more
-1
250 mm or less
For bizhub 180 / bizhub 210
Setting value
2
1
"0"
(default value)
-1
60
ing up for fusing performance that changes with the operating environment or
type of paper.
"0"
Setting range : -1 to +2
Paper width
CD
361 mm or more
360 mm or less
361 mm or more
360 mm or less
361 mm or more
360 mm or less
361 mm or more
360 mm or less
Paper width
221 mm or more
220 mm or less
221 mm or more
220 mm or less
221 mm or more
220 mm or less
221 mm or more
220 mm or less
Field Service Ver. 1.0 Apr. 2005
Mode selected in Service's Choice
Mode 1
FD
Fusing Heater Lamp temperature
200 °C
200 °C
200 °C
200 °C
200 °C
190 °C
190 °C
190 °C
180 °C
180 °C
180 °C
170 °C
Mode selected in Service's Choice
Mode 1
Fusing Heater Lamp temperature (main/sub)
200 °C
190 °C
180 °C
170 °C
Mode 3
190 °C
190 °C
185 °C
180 °C
180 °C
175 °C
170 °C
170 °C
165 °C
160 °C
160 °C
155 °C
Mode 3