Select System > LLDP > Global Configuration.
7.
In the Transmit Interval field, enter the interval in seconds to transmit LLDP frames.
8.
The range is from 5 to 32768 secs. The default value is 30 seconds.
In the Transmit Hold Multiplier field, enter the multiplier on Transmit Interval to assign TTL.
9.
The range is from 2 to 10 secs. The default value is 4.
In the Re-Initialization Delay field, enter the delay before re-initialization.
10.
The range is from 1 to 10 secs. The default value is 2 seconds.
In the Notification Interval field, enter the interval in seconds for transmission of
11.
notifications.
The range is from 5 to 3600 secs. The default value is 5 seconds.
Click the Apply button.
12.
The updated configuration is sent to the switch. The changes take effect immediately but
are not retained across a power cycle unless a save is performed.

Configure the LLDP Interface

To configure the LLDP interface:
Prepare your computer with a static IP address in the 169.254.100.0 subnet, for
1.
example, 169.254.100.201.
Connect an Ethernet cable from an Ethernet port on your computer to an Ethernet port on
2.
the switch.
Launch a web browser.
3.
Enter the IP address of the switch in the web browser address field.
4.
The default IP address of the switch is 169.254.100.100.
The Login screen displays.
Enter the user name and password.
5.
The default admin user name is admin and the default admin password is blank, that is,
do not enter a password.
Click the Login button.
6.
The web management interface menu displays.
M6100, M5300, and M7100 Series Managed Switches