Stopping; Emergency Stop Switch - Shindaiwa DGW300MS Owner's And Operator's Manual

Shindaiwa diesel engine generator & welder vertical, water-cooled 4-cycle diesel engine
Table of Contents

Advertisement

<Caution>
Do not drive the starter motor for more than 15
seconds successively.
If you need to restart, wait for 30 seconds or
more before retry.
Once the engine has started, never turn the
starter switch to [START].
Restart after stopping due to fuel shortage
This equipment is incorporated in automatic
vacuuming air feature. Therefore, even though the
engine stops due to running out of fuel, you can restart the engine easily by the
following steps.
① Turn the Starter Switch to [STOP].
② Fill the fuel.
③ Turn the Idle Control Switch to [AUTO].
④ Turn the Starter Switch to [START] and drive the starter motor for about 10
seconds.
⑤ Release the Starter Switch, as promptly as the engine started.
⑥ Wait for about 1 minute to vacuum the air out. The engine speed becomes
stable when the air is extracted.
<Caution>
Never turn the engine HIGH speed or connect the loads until the air is extracted
completely (the engine speed becomes stable)

7-2. Stopping

① Turn (Push-down) the breakers (MAIN, 1-P) to [OFF].
② Turn the Idle Control Switch to [AUTO].
③ Keep the engine idle (cooling down) for about 5 minutes.
④ Turn the Starter Switch to [STOP].
⑤ After the engine has stopped, turn the every Fuel Lever to [CLOSE].
⑥ Turn the Battery Isolator Switch to [OFF] position.
<Caution>
When the engine does not stop in spite of turning the Starter switch to [STOP],
Turn the Fuel Lever on Fuel Strainer or Water Separator to [CLOSE], then the
engine will stop in a few minutes.
In this case, be sure to consult with our authorized distributor or our engineering
section and ask to repair.
Do not attempt to turn to [STOP] position while actual welding or utilizing AC
power source, it may cause the serious damage on the unit.
7-3. Emergency Stopping
The Emergency Stop feature is incorporated in the
equipment.
Push the Emergency Stop Switch in case of an
emergency or equipment abnormality during
operation.
① Push the Emergency Stop Switch to stop
engine in an emergency case.
<Caution>
Be sure to return the Starter Switch to [STOP] after
the engine stops.
Never hit the Emergency Stop Switch by any tool such as a hammer.
Never use the Emergency Stop Switch except an emergency case.
Turn the Fuel Lever on Fuel Strainer or Water Separator to [CLOSE] to stop in the
case the Emergency Stop Switch does not function.
IDLE
CONTROL
SWITCH
- 18 -
STARTER
SWITCH
STARTER
EMERGENCY
SWITCH
STOP
SWITCH