Operation - Shindaiwa DGW300MS Owner's And Operator's Manual

Shindaiwa diesel engine generator & welder vertical, water-cooled 4-cycle diesel engine
Table of Contents

Advertisement

Applicable Load (For reference purpose only)
Electric Bulb, Heater, etc.
electric Tools, etc (Series Motor),
Mercury Bulb (High Power Factor Type)
Submersible Pump, Compressor, etc
(Induction Motor)
Series Motor : Motor with brush
Induction Motor : Brushless Motor
The value described is OUTPUT for Induction Motor loads and
POWER CONSUMPTION for the other equipment.
<Caution>
Be sure to use the frequency designated in the equipment incorporated in mercury
bulb or induction motor.
The load incorporated in motor may require bigger power than the rated power
consumption. Therefore, consult with our authorized distributor or our engineering
section to clarify.
When connecting to use 2 or more sets, start the load one by one, not to start them
simultaneously.
When switching a Mercury bulb ON again, wait for 15 minutes (about) until it cools
down.

9-3. Operation

Danger : Electric Shock
Before connecting or disconnecting a load cable from the receptacles,
always turn the circuit breakers (MAIN, 1-P) to [OFF] position. And always
stop engine, and remove the engine key. A person performing the
maintenance should always keep the key.
Ground the every grounding terminal to the earth as set out in the manual.
If even one of all is unconnected by mistake or accident, it will be much
more dangerous for human than the NO-RELAY case, because leaking
current inevitably goes through the body. (Refer to 5-7. Earth Leakage
Circuit Breaker and Grounding )
Even though all the current leakage relays in the loads have been grounded
to the earth, the earth grounding terminal and the bonnet (canopy) should
be grounded to the earth.
Grounding should be made after the engine is stopped.
Whenever the current leakage breaker activates, you should repair the
leaking place first of all.
Caution : Injuries
Be sure to connect to output terminals or insert a plug to a receptacle, after
confirming that all the switches in the loads are positioned to [OFF].
Caution : Damage to the property Aftermath
Whenever connecting to use medical equipment or appliances, be sure to
consult with the medical equipment company, doctor or hospital personnel.
<Caution>
Turn the Operation Mode Selector Switch to [GEN. WELDER] or [GEN. ONLY]
while selecting AC generator output. The AC output is not supplied when the
Operation Mode Selector Switch is [WELDER ONLY] mode.
The AC Volt meter reads 1-P output voltage, apart from the circuit breakers
(MAIN, 1-P) positions to [ON] or [OFF], when the engine is driving.
Loads
- 22 -
Capacity (kW)
1-Phase 240 V
Receptacle
Receptacle
1 set
2 set use
3.6
1.8
1.4
1.4
7.2
3.6
2.8
2.8