Operation Mode Selector; Meter - Shindaiwa DGW300MS Owner's And Operator's Manual

Shindaiwa diesel engine generator & welder vertical, water-cooled 4-cycle diesel engine
Table of Contents

Advertisement

(5) Circuit Protector for Wire Feeder
When the over current (more than 5A) is flown into 14-Pin Connector for wire feeder,
the Circuit Protector will be activated to shut off the current.
<Caution>
Resolve the over current issue to proceed the necessary maintenance when the
Circuit Protector was activated, with reset the trip button.
(6) 9-Pin Connector (Remote Control)
Remote Control operation is
available by connecting the
compatible Remote Controller
to the 9-Pin Connector. Adjust
the welding current (in CC
condition) or welding voltage (in
CV condition) in the remote
area from the machine.
< Caution >
• When the remote control box is
connected, the current adjustment dial of the equipment's front panel will not work.
• When the plug of remote control box has disconnected while welding, the current
adjustment dial of the equipment will work. It may affect to increase or decrease the
current accidentally.

5-5. OPERATION MODE SELECTOR

The equipment incorporates Operation Mode Select feature.
Below three modes can be selected by the Operation Mode Selector Switch position.
[GEN. WELDER]
[WELDER ONLY]
[GEN. ONLY]

5-6. Meter

The equipment incorporates digital meters, voltage & amperage of welding output
and also 1-Phase Voltage & frequency of AC output.
(1) DC Ampere Meter Volt Meter
Each meter displays welding voltage and amperage.
<Caution>
While operating at no-load, if the CV/CC Selector Switch is set as [CV-WIRE], DC
Volt Meter is indicating desired voltage by Output Control Dial.
(There is no display at DC Ampere Meter while no-load.)
While operating at no-load, if the CV/CC Selector Switch is set as [CC-STICK,
GOUGING], DC Ampere Meter is indicating desired amperage by Output Control
Dial. (There is no display at DC Volt Meter while no-load.)
During actual welding work, both DC Volt Meter Ampere Meter displays actual
output. Both displays will be back to the pre-set value after counting about
8seconds with blinking dot on the DC Volt meter.
(2) AC Meter
The meter displays the 1-Phase voltage and the frequency in AC output.
<Caution>
While Operation Mode Selector Switch is [GEN. WELDER] or [GEN. ONLY],
AC Meter displays 1-Phase voltage and frequency. When the Operation Mode
Selector Switch is [WELDER ONLY], AC Meter display will goes off.
Both Welder and Generator mode
Only welding function mode
Only generating function mode
- 10 -
9-PIN CONNECTOR
REMOTE
CONTROLLER
(Compatible)