9-4. Stopping Operation

CAUTION : BURNS
 Do not touch the engine and surrounding components immediately after stopping the
engine as they are still extremely hot.
(1) Manual Stop
Turn the switches and breakers on the load side to OFF.
1
Turn the three-phase and single-phase breakers on the operation panel to OFF.
2
Confirm that the "ACCESSORY" switch is set to OFF.
3
Turn the Throttle switch to IDLING.
4
The engine cools down for approximately three minutes.
5
Turn the starter switch to STOP.
6
< Note >
 Never turn accessory switch ON during operation. The engine keeps running while accessory
switch is ON.
 Set the STARTER SWITCH selector to STOP position if the generator will not be used for a
prolonged period. If you leave the selector in the AUTO or START position, the standby
current may drain the battery.
(2) Auto Stop
The engine stops when the REMOTE START terminal opens.
1
Set the STARTER SWITCH selector to STOP.
2
< Note >
 Never turn accessory switch ON during operation. The engine keeps running while accessory
switch is ON.
 Set the STARTER SWITCH selector to STOP position if the generator may not be used for a
prolonged period. If you leave the selector in the "AUTO" or START position, the standby
current may drain the battery.