Generator Operation; Output Range; Output Limitation - Shindaiwa DGW300MS Owner's And Operator's Manual

Shindaiwa diesel engine generator & welder vertical, water-cooled 4-cycle diesel engine
Table of Contents

Advertisement

Caution : Fire
Keep any flammable items and combustible items away from the welding area,
as welding causes hot spatters.
Caution : Burns
Be sure to wear leather gloves, apron, shoe covers, eye protection
glasses/mask safety shoes, safety cap and long sleeve shirts, because
welding splashes spatters.
<Caution>
Make sure to turn the Operation Mode Selector Switch to [GEN. WELDER] or
[WELDER ONLY]. There would be no welding output while the Operation Mode
Selector Switch is at [GEN. ONLY] position.
(1) Welding Rod (include Gouging Rod)
① Turn the Weld Terminals Switch to [WELD TERMINALS ON].
② Turn the CV/CC Selector Switch to [CC-STICK, GOUGING].
③ Turn the Rod Selector Switch to [CELLLOSE] on cellulose rod welding or to
[OTHERS] on gouging or ordinal welding rods except cellulose rod.
④ Set the current amperage by the Output Control Dial.
⑤ Adjust the arc-strike current by turning the Arc Control Dial
(2) Semi-Automatic Wire Feeder (Weld Terminal)
■ ■ ■ ■
While not using 14-Pin Connector
① Turn the Weld Terminals Switch to [WELD TERMINALS ON].
② Turn the CV/CC Selector Switch to [CV-WIRE].
③ Set the voltage by the Output Control Dial.
■ ■ ■ ■
While using 14-Pin Connector
① Turn the 42V/115V Selector Switch to [42V] or [115V], according to the
applicable Wire Feeder.
② Connect the Wire Feeder plug into 14-Pin Connector.
③ Turn the Weld Terminals Switch to [REMOTE CONTROL]
④ Synchronize the polarity of unit with Wire Feeder display by selecting Wire
Feeder Voltmeter Switch.
⑤ Turn the CV/CC Selector Switch to [CV-WIRE].
⑥ Set the voltage by the Output Control Dial.
<Caution>
The wire feeder will not work properly if the 42V/115V Selector Switch is selected
incorrectly compare to the wire feeder rated voltage.

9 Generator Operation

9-1. Output Range

(1) 1-Phase 240V Output Receptacles
1-Phase 240V Output is available through 2
receptacle sets. Maximum output is 7.2kVA
for 2 receptacle sets.

9-2. Output Limitation

Please refer to the following table, because electric tools and home appliances
cannot be judged only by the rated output or the power consumption due to the
efficiency and character of the components.
- 21 -
1-P
RECEPTACLE

Advertisement

Table of Contents
loading

Table of Contents