Advanced Entry Calibration - Datamax I-class Maintenance Manual

Hide thumbs Also See for I-class:
Table of Contents

Advertisement

2.1.3

Advanced Entry Calibration

Advanced Entry is the alternate calibration method for special-case media types. In the procedure,
sensor readings for the label and TOF values are taken using different sampling algorithms. From this
compiled list of values the best algorithm is selected and then used to generate new readings for
manual entry into memory.
Note:
Use this method only when Standard Calibration was unsuccessful.
With the SENSOR TYPE enabled, perform an Advanced Entry Calibration by following the steps below:
Step
Action
1
Turn ON the printer.
2
Press the
raise the printhead assembly.
Press the
3
Press the
4
scroll to SENSOR
CALIBRATION.
Press the
5
then the
Press the
6
then the
Press the
Place the label under the
7
Sensor Eye Mark, and then
lower the printhead assembly.
(continued)
Adjustments and Maintenance
Displayed Message
Key, and then
Key.
Key then
SENSOR CALIBRATION
Key, and
SENSOR CALIBRATION
Key.
Key, and
Key.
GAIN TRAN
*00
Key.
Or, for reflective media:
GAIN REFL
*00
UNCALIBRATED
MENU MODE
MEDIA SETTINGS
MEDIA SETTINGS
MEDIA TYPE
MEDIA SETTINGS
ADVANCED ENTRY
ADVANCED ENTRY
SENSOR GAIN
<yyy>
<0 - 31>
<yyy>
<0 - 31>
2-4
Comment
Wait briefly, about six
seconds, for the printer to
initialize.
You are in MENU MODE.
You are in MEDIA
SETTINGS.
Press the
Key to
cancel this procedure.
Press the
Key to
cancel this procedure.
You are beginning the
procedure.
If using preprinted media,
ensure the label area under
the Sensor Eye Mark is free
of text, graphics, or
borders.
Never position a perforation
in the sensor when
recording a reading.