Datamax I-class Maintenance Manual page 17

Hide thumbs Also See for I-class:
Table of Contents

Advertisement

Step
Action
Using the
the Gain Number determined in
13
Step 12, and then press the
Key.
a) Place the media in the
sensor. Record the reading
and label it "P" (paper).
b) Place the backing, notch, or
mark in the sensor. Record
14
the reading and label it "G"
or "M" (Gap or Mark).
c) Remove media. Record the
reading and label it "E"
(Empty).
Press the
15
then press the
Press the
Using the
Key, set the Paper
Sensor Level to the value
determined in the previous
step. Then press the
16
Key to select the entry and
advance the menu.
Repeat for the Gap Sensor
Level (or Mark Sensor Level)
and the Empty Sensor Level
entries.
(continued)
Adjustments and Maintenance
Displayed Message
GAIN TRAN
*08
Key, scroll to
Or, for reflective media:
GAIN REFL
*08
GAIN TRAN
*08
Or, for reflective media:
GAIN REFL
*08
Key, and
ADVANCED ENTRY
SENSOR LEVELS
Key.
PAPER SENSOR LEVEL
P*198 G*084 E*014
GAP SENSOR LEVEL
P*198 G*084 E*014
Key.
Key or the
EMPTY SENSOR LEVEL
P*198 G*084 E*014
Or, for reflective media:
PAPER SENSOR LEVEL
P*015 M*181 E*213
MARK SENSOR LEVEL
P*015 M*181 E*213
EMPTY SENSOR LEVEL
P*015 M*181 E*213
<yyy>
<0 - 31>
<yyy>
<0 - 31>
<yyy>
<0 - 31>
<yyy>
<0 - 31>
2-7
Comment
The samplings using the
selected Gain Number are
taken.
The sensor readings must
be entered into the printer.
Selection is denoted by an
asterisk (*).
The displayed message will
change and the selection
will flash to indicate the
next entry.

Hide quick links:

Advertisement

Table of Contents
loading