NetworX Version 3 Installation Manual
Location
Term
2.6.2.1.7
Immediate Zone Restore
2.6.2.2
Diagnostics
2.6.2.2.1
Batt Missing Test
2.6.2.2.2
Dynamic Batt Test at Arming
2.6.2.2.3
Manual Siren Test
2.6.2.2.4
Manual Dialer Test
2.6.2.3
Clock
2.6.2.3.1
Use Int.Crystal for Clock
2.6.2.3.2
Lost Clock Indication
2.6.2.3.3
Summer/Winter Time
2.6.2.4.1
Steady Siren (Fire)
2.6.2.4.2
User Code Resets Tamper
Memory
2.6.2.4.3
Use GSM If Line Trouble
2.6.2.4.4
First Alarm Logic
Definition
A menu option that sets the way zones are restored. When
it is On, the zones restore immediately. In this case all the
alarms and restores are sent as they occur even in case of
multiple alarms. When this option is Off, the zones restore
only when the siren is off or disarmed. In this case a second
or subsequent alarm will not be sent until the siren times
out.
A menu entry that groups test options. These options
specify the tests that can be performed on the control
panel.
A menu option that enables a test to determine whether
the battery is connected to the system. This test is usually
performed automatically when the system is first powered
up and periodically thereafter.
A menu option that enables a dynamic battery test at
arming. This is an automatic test carried out by the control
panel at the moment of arming to ensure the battery is
working properly. The panel lowers the battery charging
voltage in order to draw current from the battery. If the
system is not armed between 00:01 and 23:59, the test is
performed at 00:00.
A menu option that activates the siren test when the LCD &
Self Test command is selected from the user menu.
A menu option that includes a dialer test in the user's
manual test. A manual test call is made to the central
station and the corresponding signal is transmitted.
A menu entry that groups options that configure the clock.
A menu option that provides an accurate clock in situations
where different mains frequencies are used: 50 Hz or 60 Hz
are possible selections.
A menu option that enables the service message 'Panel
Loss of time'.
A menu option that allows automatic switching of summer
and winter time.
A menu option that sets the type of siren activated when a
fire alarm occurs. This can be either yelping or temporal.
A menu option that allows a user to reset the system after a
tamper alarm. If this option is disabled, an installer must
reset the system each time a tamper occurs. The user
should identify the cause of the alarm before arming the
system and contact the installer if necessary.
A menu option that specifies the backup phone number
over GSM. This phone number is used when the on-board
dialer fails.
A menu option that enables first alarm logic. This feature
affects the way multiple alarms are displayed on a keypad.
If this option is enabled and multiple alarms occur during an
armed cycle, the keypad will display the first tripped zone
only before disarming. After disarming, the first zone tripped