GE NetworX V3 Installation Manual page 211

Alarm system
Table of Contents

Advertisement

Table 30.
Reporting syntax
Format key
>
aaaaaa
ee
nnn
Rin
.
/
[X]
[X ...]
The settings and events in Table 31 are transmitted in the following messages.
>123456 BA001 BA003.
>987654 YT000.
>345678 TA030.
Table 31.
Example settings and events
Setting
System account code for the given destination
Partition 1 account code
Partition 3 account code
BA on zone 1
BA on zone 3
Low battery on panel
TA on zone 30
Combined events
Account codes are used to identify partitions. Events for separate accounts codes can be sent in the
same message using the syntax:
aaaaaa eennn [eennn ...][/aaaaaa eennn [eennn ...]...].
See Table 30 for a detailed syntax description.
The settings and events in Table 31 are transmitted in the following message.
>123456 BA001 BA003/987654 YT000/345678 TA030.
Description
The message opening character.
A six-digit account code.
A two-digit SIA code.
A three-digit number, e.g. zone number.
Partition modifier, 'Ri' is literal, n is the partition number.
The message closing character.
Separator
X is optional
X is optional and may be repeated one or more times.
NetworX Version 3 Installation Manual
Value
987654
123456
345678
Partition 1
Partition 1
YT000
Partition 3
211