GE NetworX V3 Installation Manual page 155

Alarm system
Table of Contents

Advertisement

entering codes. The way the functions actually work depends on other system settings, for example
the Arm Away function works as a single-button shortcut only in the single-partition mode if the
Installer Menu>Control Panel>Partition Settings>Partition 1>Feature Select>Arming>Quick Arm
menu option was set. Some functions are assigned to particular keys by default, and can be made
permanent (fixed) at the factory.
Note: When arming the system with a function key, both logs and reports show User 98 as the user who armed the
system.
There are the following default key assignments:
Table 18.
Default function key assignments
Key
Default function
F1
Panic Keypad
F2
Fire Alarm
F3
Arm Away (factory fixed key)
F4
Arm Stay (factory fixed key)
F5
Disarm (works in Master Mode only) (factory fixed key)
F6
Select zones to bypass (factory fixed key)
F7
Arm in Night Mode
F8
Medical
You can program any function key, unless it is fixed at the factory. The following example
configures the F1 key so it performs the manual fire alarm function.
Navigate with the
1.
OK.
Scroll to F1 Function>Fire Alarm and press OK.
2.
The keypad beeps once to confirm the change and returns to F1 Function.
3.
Navigate with the
4.
Select>Keypads>Fire/Aux 1 and press OK.
Select Enabled and press OK.
5.
The keypad beeps once to confirm the change and returns to Fire/Aux 1.
6.
Table 19.
Available function key actions
Function
Action description
Disabled
Disables the function key.
Arm Away Mode
Arms the system in Away mode. Arming with the function key will report as User 98.
Note: This shortcut works only if the Quick Arm menu option was set. It works differently in
the master mode and in the single-partition mode. For more information, see the Master
Keypad, and the Quick Arm menu option descriptions in the glossary.
Arm Stay Mode
Arms the system in Stay mode. Arming with the function key will report as User 98.
Note: This shortcut works only if the Quick Arm menu option was set. For the Stay mode to
work correctly, interior zones must be set. It works differently in the master mode and in the
single-partition mode. For more information on this button behaviour, see the Master
Keypad, and the Quick Arm menu option description in the glossary.
Bypass Zones
Selects a zone to bypass. It is a shortcut for the User Menu>Bypass Zones menu option.
keys to Installer Menu>This Keypad>Function Keys and press
keys to Control Panel>Partition Settings>Partition 1>Feature
NetworX Version 3 Installation Manual
155

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents