LOCATION 52 - OPENING TIME/AUTOMATIC DISARMING TIME (2 segments, numerical data)
Location 52 contains the time (in 24 hour format) when the NetworX V3 will enable the disarm
capability for codes designated as 'arm only after closing'. This time is only valid on those days
programmed in location 54. This is also the time when the panel will automatic disarm.
Note: Opening time must be earlier than closing time so that auto arm, Aux. outputs, or code authorisation can
function properly.
Segment 1
Program the hour of the opening time
Segment 2
Program the minutes after the hour of the opening time
LOCATION 53 - CLOSING TIME/AUTOMATIC ARMING TIME (2 segments, numerical data)
Location 53 contains the time (in 24 hour format) when the NetworX V3 will disable the disarm
capability for codes designated as 'arm only after closing'. This is also the time when the automatic
arming sequence will begin (if this option is enabled in location 55).
Note: Opening time must be earlier than closing time so that auto arm, auxiliary outputs, or code authorisation can
function properly.
Segment 1
Program the hour of the closing / auto arm time
Segment 2
Program the minutes after the hour of the closing / auto arm time
LOCATION 54 - DAYS OF THE WEEK "ARM ONLY AFTER CLOSE WINDOW" CODES FUNCTION IN
PARTITIONS 1 THRU 4 (4 Segments, feature selection data)
Location 54 selects the days of the week on which each partition is open. On these days, "arm only
after close window" codes will be able to arm and disarm during "open window". On days not
selected here, "arm only after close window" codes will not disarm. Segment 1 is for partition 1, and
segment 4 is for partition 4 (see locations 52 and 53 for the opening and closing times for the open
days).
Segment 1-4
LOCATION 55 - DAYS OF THE WEEK FOR AUTO ARMING IN PARTITIONS 1 THRU 4 (4 segments,
feature selection data)
Location 55 selects the days on which each partition will auto-arm. Segment 1 is for partition 1, and
segment 4 is for partition 4. If a zone is faulted before the warning timer and stays faulted during the
1 =
"Arm only after close window" will arm/disarm on Sunday
2 =
"Arm only after close window" will arm/disarm on Monday
3 =
"Arm only after close window" will arm/disarm on Tuesday
4 =
"Arm only after close window" will arm/disarm on Wednesday
5 =
"Arm only after close window" will arm/disarm on Thursday
6 =
"Arm only after close window" will arm/disarm on Friday
7 =
"Arm only after close window" will arm/disarm on Saturday
8 =
Reserved