GE NetworX V3 Installation Manual page 81

Alarm system
Table of Contents

Advertisement

Location
Term
2.4.2.5
Answer Machine Defeat
2.4.2.6
Call PC on Autotest
2.4.2.7
Require Code for Download
2.4.2.8
Lockout
2.4.2.8.1
System Shutdown
2.4.2.8.2
Local Programming
2.3.2.8.3
Comms Settings
2.4.2.8.4
Download Settings
2.4.3
Autotest
2.4.3.1
Hours/Days?
2.4.3.2
Interval
NetworX Version 3 Installation Manual
Definition
A menu entry used to defeat an answering machine. If two-
call Answer Machine Defeat AMD is enabled, two telephone
calls are required to defeat the answering machine. On the
first call, the phone rings once or twice. The control panel
detects the rings and starts a 45-second timer. During this
timer, the control panel answers the next call on the first
ring. This is not recommended for commercial applications.
A menu option that allows the panel to use call back when
the central station performs an autotest. After the test
report is delivered to the central station, the panel calls the
up/download software using the call back phone number.
Actions, such as upload event log and download phone
numbers, can be selected in the up/download software.
A menu option that requires a user code to be entered
before downloading can start.
A menu entry that groups options that lock certain system
functions.
A menu option that allows the up/download software to
shutdown the control panel. This option can be set only
from the up/download software. The shutdown LCD
message is shown to explain the reason for the shutdown.
During shutdown the system is completely inactive. It is not
possible to arm/disarm the system and no reports or sirens
are activated.
A Communications menu option that disables the installer
menu. This option can be set only through the
up/download software.
A menu option that prevents the installer changing the
communication settings (telephone numbers, account
codes and so on). This option must be set using the
up/download software.
A menu option that prevents the installer changing the
following download settings:
Answer Machine Defeat
Callback Required
Lockout>System Shutdown
Lockout>Local Programming
Lockout>Comms Settings
Lockout>Download Settings
Call PC on Autotest
This option must be set through the up/download
software.
A menu entry that groups options that configure the
automatic test run by the system.
A menu option that specifies whether the autotest occurs
after a specified number of days or hours. The autotest can
be suppressed if another report has been sent.
A menu option that sets the length of time between
autotests. The basic unit is set in the Hours/Days? option.
The Hour and Minute options set the time at which the test
81