If you need to report openings and closings with a unique code per user, Contact ID or SIA format
must be used.
Segment 1
Closing code for partition 1
Segment 2
Closing code for partition 2
Segment 3
Closing code for partition 3
Segment 4
Closing code for partition 4
LOCATION 79 - AUTOTEST COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (2 segments,
numerical data)
Location 79 contains the tens and ones digits for a 4+2 and 3+1 format that will be sent if "Autotest"
or "Manual Test" is enabled. Segment 1 contains the tens digit, and segment 2 contains the ones
digit.
For a 3+1 format, only the segment 1 digit (tens) will be sent.
LOCATION 80 - RECENT CLOSING AND EXIT ERROR COMMUNICATOR CODE, SLOW SPEED
FORMATS ONLY (2 segments, numerical data)
Location 80 contains the tens digit for a 4+2 and 3+1 format that will be sent if "Recent Closing"
and/or "Exit Error Reporting" is enabled. Segment 1 contains the tens digit for the "Recent Closing
Reporting". Segment 2 contains the tens digit for the "Exit Error Reporting". The ones digit is the
ones digit of the user number that did the opening. If the user is greater than 9, the numbers will
begin repeating (e.g. code 6 = 6, code 45 = 5).
If you need to report Recent Closings and Exit Errors with a unique code per user, Contact ID or SIA
format must be used.
LOCATION 81 - START PROGRAM AND END PROGRAM COMMUNICATOR CODES, SLOW SPEED
FORMATS ONLY (4 segments, numerical data)
Location 81 contains the tens and ones digits for a 4+2 and 3+1 format that will be sent if "Start /
End Programming Reporting" is enabled. Segment 1 contains the tens digit of the "Start Program
Reporting". Segment 2 contains the ones digit of the "Start Program Reporting". Segment 3 contains
the tens digit of the "End Program Reporting". Segment 4 contains the ones digit of the "End
Program Reporting".
For a 3+1 format, only the segment 1 digit resp. segment 3 digit (tens) will be sent.
LOCATION 82 - END DOWNLOAD COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (4
segments, numerical data)