GE NetworX V3 Installation Manual page 86

Alarm system
Table of Contents

Advertisement

86
NetworX Version 3 Installation Manual
Location
Term
2.4.4.3.6.3
Cancel
2.4.4.3.6.4
Recent Closing
2.4.4.3.6.5
Start/End Programming
2.4.4.3.6.6
End Download
2.4.5
Custom Format
2.4.5.1
Features 1
2.4.5.2
Features 2
2.4.5.3
Inter-Digit Time
2.5
Partition Settings
2.5.1.1
Timers
2.5.1.1.1
Entry Time 1
2.5.1.1.2
Exit Time 1
Definition
A menu option that enables cancel reporting. A cancel
report is sent to the central station when the system is
disarmed (within the time specified by the dialer delay)
after an alarm.
A menu option that sends a report to the central station if
an alarm occurs within five minutes after the panel has
been armed. The user number that armed the system is
also sent.
A menu entry that groups the reporting codes sent to the
central station when programming starts, and when the
installer leaves programming mode.
A menu entry that groups the report codes sent to the
central station when downloading is complete.
A menu option that allows you to build communication
formats if using a non-standard central station. Consult
technical support before using this option and the related
options.
A menu option that allows you to configure your own
reporting protocol based on the options enabled. Consult
technical support before using this option and the related
options.
A menu option that allows you to configure your own
reporting protocol based on the options enabled. Consult
technical support before using this option and the related
options.
A menu option that sets the inter-digit time for custom
pulse format (time between output digits). The inter-digit
time is the value programmed on this location, divided by
the pulse-rate (PPS) of the programmed format. For
example, when the value 10 is programmed here and a
pulse format of 20 PPS is used, the inter-digit time is 10/20
= 0.5 sec. Consult technical support before using this
option and the related options.
A menu entry that groups all partition settings. These
settings include partition features, partition timers and so
on.
A menu entry that groups timer options.
A menu option that sets the time within which the user
must disarm the partition before a full alarm occurs. This
time can be between 10 and 255 seconds.
A menu option that sets the time within which the user
must leave the protected zone after arming the partition
before a full alarm occurs. When arming in Away mode, the
keypad can beep to warn the user (see keypad menu
options), also System Arming, Leave Now screen displays
until the end of the exit delay time. This time can be
between 10 and 255 seconds.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents