GE NetworX V3 Installation Manual page 111

Alarm system
Table of Contents

Advertisement

arm/disarm codes and the installer code are 6 digits. If this option is enabled,
the default user 1 code is [1]-[2]-[3]-[4]-[5]-[6].
Note: If you enable this option, verify that the installer code is a six-digit code
2 =
On: requires code entry for the perform callback download function and the
answer incoming call for download function
3 =
On: enables Auto Cancel / Abort
4 =
Reserved
5 =
On: keypad shutdown mode
6 =
On: user authorization to enter program mode
7 =
On: codes 16 and 17 are guard codes
8 =
Reserved
LOCATION 42 - INSTALLER CODE (6 segments, numerical data)
Location 42 contains the installer code ("Go To Program" code). This location contains a code with
either 4 or 6 digits. If the 6-digit code option is enabled in Location 41, THIS CODE MUST
CONTAIN SIX (6) DIGITS. If this option is not enabled in location 41, the last 2 segments (digits)
will be ignored. With the NetworX system disarmed, the installer code can be used to enter the
program mode.
LOCATION 43 - GO TO PROGRAM CODE PARTITION AND AUTHORIZATION (2 segments,
feature selection data)
The "Go To Program Code" can be used as a standard arm/disarm code. When using the code to arm
or disarm, the user ID is 255. (It is not possible to change this code in the run mode).
Segment 1
1 =
2 =
3 =
4 =
5 =
6 =
7 =
8 =
Segment 2
1 =
2 =
3 =
4 =
LOCATION 44 - DURESS CODE (6 segments, numerical data)
Location 43 contains the "Duress" code. This Location contains either 4 or 6 digits. If the 6-digit
code option is enabled in location 41, THIS CODE MUST CONTAIN SIX (6) DIGITS. If the 6-digit
option is not enabled in location 41, the last 2 digits will be ignored. If the duress code is
programmed, it will work for all partitions.
before you exit from programming
Reserved
On: enables "Go To Program Code" as an arm only code
On: enables "Go To Program Code" as an arm only, after closing
On: enables "Go To Program Code" as a master arm/disarm code (can change user codes)
On: enables "Go To Program Code" as an arm/disarm code
On: enables "Go To Program Code" to bypass zones
On: enables "Go To Program Code" opening and closing reports
Reserved
On: enables the "Go To Program Code" for partition 1
On: enables the "Go To Program Code" for partition 2
On: enables the "Go To Program Code" for partition 3
On: enables the "Go To Program Code" for partition 4
NetworX Version 3 Installation Manual
111

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents