GE NetworX V3 Installation Manual page 189

Alarm system
Table of Contents

Advertisement

LOCATION 71 - PROGRAMMING SPECIAL FUNCTIONS AND PARTITIONS FOR OUTPUT 1 (2
segments, feature selection data)
Segment 1 - selects the following special conditions
Option
Function
1
ON
If output should time in minutes
OFF
If output times in seconds
2
ON
Output "Latch": should latch until a code is entered
OFF
Output is timed
3
ON
Timed or output should be reset if a code is entered while it is being timed
OFF
Stays timed (not reset) after code is entered
8
Reserved
Segment 2 - selects the following partitions
Option
Function
1
ON
If the event should activate when it occurs in partition 1
2
ON
If the event should activate when it occurs in partition 2
3
ON
If the event should activate when it occurs in partition 3
4
ON
If the event should activate when it occurs in partition 4
LOCATION 72 - PROGRAMMING THE X-10 LOCATION FOR OUTPUT 1 (2 segments, numerical
data)
Segment 1 - Unit code
Program a number from 0-15 to represent the corresponding X-10 unit code from the following table.
Module
1
2
Segm 1
0
1
Segment 2 - House code
Program a number from 0-15 to represent the corresponding house code from the following table.
X-10 Location code (house code)
0=A
4=E
8=I
1=B
5=F
9=J
2=C
6=G
10=K
3=D
7=H
11=L
3
4
5
6
7
2
3
4
5
6
12=M
13=N
14=O
15=P
NetworX Version 3 Installation Manual
8
9
10
11
7
8
9
10
12
13
14
15
11
12
13
14
189