Any new IO module is learned-in by default as a universal siren, i.e. its both outputs are triggered by
the Any Siren event. In order to assign another trigger, you have to select an appropriate event under
RF Receivers>RF Receiver 32>Outputs>I/O x Output y>Event.
You can program the event triggering a particular output, set time the output is on (in minutes or
seconds, or until the user code is entered), and assign user permissions to activate outputs. The
following example sets the event triggering the output 1 on the IO module 3 as Not Ready to Arm.
The partition selected to trip this output is partition 1. The output is switched on for 6 minutes.
Navigate with the
1.
Scroll to I/O 3 Output 1 and press OK.
2.
Select Event>Not Ready to Arm and press OK.
3.
The keypad beeps once to accept the change and returns to Event.
4.
Navigate with the
5.
The keypad beeps once to accept the change and returns to Time Unit.
6.
Navigate with the
7.
The keypad beeps once to accept the change and returns to Time.
8.
Navigate with the
9.
OK.
The keypad beeps once to accept the change and returns to Partitions.
10.
Note: Activation time of the external siren can be between 3 and 15 minutes.
The following example sets the event that switches on the output 2 on the IO module 4 as Follow
X10 Commands. The IO module behaves then like a standard X10 device. The X10 unit code
assigned to this output is 5 and the X10 house code is P.
Navigate with the
1.
Scroll to I/O 4 Output 2 and press OK.
2.
Select Event>Follow X10 Commands and press OK.
3.
The keypad beeps once to accept the change and returns to Event.
4.
Navigate with the
5.
The keypad beeps once to accept the change and returns to Unit Code.
6.
Navigate with the
7.
The keypad beeps once to accept the change and returns to House Code.
8.
The list of events that can be selected during IO module programming is as follows:
Table 22.
RF receiver output events
Nr.
Event
0**
Burglary alarm
1**
Fire alarm
2**
24 hour alarm
4**
Tamper Alarm
keys to RF Receivers>RF Receiver 32>Outputs and press OK.
keys to Time Unit and press OK. Select Minutes and press OK.
keys to Time, enter 6 and press OK.
keys to Partitions and press OK. Select partition 1 only and press
keys to RF Receivers>RF Receiver 32>Outputs and press OK.
keys to X10 Address>Unit Code, enter 5 and press OK.
keys to X10 Address>House Code, scroll to P and press OK.
Nr.
Event
18
Entry
19
Exit
20
Entry or exit
21
Armed
Nr.
Event
26
Fire trouble
45**
Code entry
46
Key FOB function 1
47
Key FOB function 2