Advanced Function Setting Level

The Advanced Function Setting Level is used for
optimizing Controller performance. To move to this
level, input the password ("−169") from the Initial Set-
ting Level.
To be able to enter the password, the Initial Set-
ting/Communications Protect parameter in the Pro-
tect Level must be set to 0.
Moving to Advanced Function Setting
Level
1
Move from the Operation Level to the Protect
Level.
2
Display the Initial Setting/Communications
Protect parameter.
icpt
1
3
Change the set value to 0.
4
Move
from
Operation Level to the Initial Setting Level.
5
Display the Move to Advanced Function
Setting Level parameter.
amov
0
6
Change the set value to −169.
7
The Advanced Function Setting Level is
displayed.
init (INIT) will be displayed.
• The parameters in this level can be used when the
Initial Setting/Communications Protect parameter
is set to 0.
• To switch between setting levels, press the O Key.
• To change set values, press the U and D Keys.
E5@C Digital Temperature Controllers User's Manual (H174)
Initial Setting/
Communications Protect
Set 0. Default: 1
the
Protect
Level
to
Move to Advanced
Function Setting Level
Set −169. Default: 0
Power ON
Operation
Level
Press the
O Key for less than 1 s.
Press the
O Key for
Press the
at least 1 s
O Key for
to flash
at least 1 s.
the
display.
Initial Setting Level
Press the
O Key for less than 1 s.
Press the
Password input
O Key for
set value −169
at least 1 s.
Advanced Function
Setting Level
the
6 Parameters
Adjustment
Level
Press the O Key for at
25
least 3 s.
100
Control stops.
Communi-
cations
Setting Level
Control in progress
Control stopped
6 - 59