6 Parameters
pf
• This parameter sets the function of the PF Key.
Function
• The default is SHFT (Digit Shift).
Setting
OFF: off
RUN: run
STOP: stop
R-S: r-s
AT-2: at-2
AT-1: at-1
LAT: lat
A-M: a-m
PFDP: pfdp
000
SHFT: shft
*1
When AT cancel is specified, it means that AT is cancelled regardless of whether the AT
currently being executed is 100% AT or 40% AT.
*2
Alarms 1 to 4, the HB alarm, and the HS alarm are cancelled.
*3
For details on auto/manual operations using the PF Key, refer to 5-12 Performing Manual
Control.
*4
This function will be disabled if it is selected for heating and cooling control or for floating control
with a Position-proportional Model.
Related Parameters
See
See
Monitor/Setting Item 1 to 5 (Advanced Function Setting Level): Page 6-87
6 - 86
PF Setting
Set value
Setting
Disabled
RUN
STOP
Reversing RUN/STOP
operation
100%AT
Execute/Cancel
40%AT
Execute/Cancel
Alarm Latch Cancel
Auto/Manual
Monitor/Setting Item
Digit Shift
Function
Does not operate as a function key.
Specifies RUN status.
Specifies STOP status.
Specifies reversing RUN/STOP operation status.
Specifies reversing 100% AT Execute/Cancel status.
Specifies reversing 40% AT Execute/Cancel status.
Specifies canceling alarm latches.
Specifies reversing Auto/Manual status.
Specifies the monitor/setting item display. Select the
monitor/setting item using the Monitor/Setting Item 1 to 5
parameters (Advanced Function Setting Level).
Operates as a Digit Shift Key when settings are being
changed.
E5@C Digital Temperature Controllers User's Manual (H174)
*1
*1 *4
*2
*3