HZ54EPV
Steps 8 & 9 for NG unit only:
8) Loosen 6 screws that secure the burner extenders. on burner tray,
located behind the burner on either side of the pilot assembly.
9) Lift out the 2 burner tray extenders.
Burner tray
Burner tray extenders
10) After extenders have been removed. Remove the 2 screws that
secure the burner tray, at the base of the fi rebox.
11) Slide the burner to the left and lift it out.
Location of screws securing burner
12) Remove 8 screws to remove the fan access panel cover - located on
the left hand side fl oor of the fi rebox.
Fan Access Panel
918-903a
FAN INSTALLATION
Burner tray extenders
15) Attach the ground wire from the fan to the ground lug in the unit. The
2
13) Manoeuvre the fan into position on the fl oor of the unit. Tilt the fan
to get through the fan access panel and into position.
14) Secure the fan to the fl oor of the unit with 2 screws.
*See wiring diagram in manual.
ground lug is located just in front of the receptacle box on the left
side on the fl oor of the unit. Plug in fan.
If installing a GTMF system - go to step 20 before proceeding.
Ground Lug
16) Slide the thermodisc into the bracket on the bottom side of the fan
access panel - check fan access panel gasket - replace if necessary.
Regency Horizon HZ54E-10 Gas Fireplace
installation
|
11/03/10
43
|
43