Rigid Pipe Venting Systems; Basic Horizontal & Vertical Terminations - Regency HZ54E-NG10 Owners & Installation Manual

Regency horizon hz54e gas fireplace
Hide thumbs Also See for HZ54E-NG10:
Table of Contents

Advertisement

Rigid Pipe Vent Systems offer a complete line of
component parts for installation of both horizontal
and vertical installations. Many items are offered
in decorative black, as well as galvanized finish.
The minimum components required for a basic
Horizontal Termination are:
1
AstroCap XL Termination Cap
1
90
elbow
o
1
Rigid Pipe Adaptor
1
Wall Thimble
1
Length of rigid pipe to suit wall thickness
The minimum components required for a basic
Vertical Termination are:
1
Vertical Termination Cap
1
Rigid Pipe Adaptor
1
Lengths of pipe to adequately
penetrate roof
1
Ceiling Firestop
1
Flashing
1
Storm Collar
Wall thickness
is measured from the back
standoffs to the inside mounting surface of
termination cap. For siding other than vinyl, furring
strips may be used, instead of a vinyl siding
standoff, to create a level surface to mount the
vent terminal. The Terminal must not be recessed
into siding. Measure the wall thickness including
furring strips.
If a Vinyl Siding Standoff is required (it must be
used with vinyl siding), measure to outside surface
of wall without siding and add 2 inches.
WarninG:
Do not combine venting components from
different venting systems.
Exception: However, use of the the AstroCap
XL
is acceptable with all systems.
TM
This product has been evaluated by Intertek for
using a Rigid Pipe Adaptor in conjunction with
Simpson DV Pro, Metal-Fab Sure-Seal, ICC
Excel and Selkirk Direct-Temp systems. Use
of these systems with the Rigid Pipe adaptor
is deemed acceptable and does not affect the
Warnock Hersey/Intertek listing of components.
The FPI AstroCap XL
Direct-Temp. AstroCap XL
proprietary trademarks of Simpson Dura-Vent Co. Inc.

riGid pipe VentinG sYsteMs

Basic HoriZontal & Vertical terMinations
is certified for installations using FPI venting systems as well as Simpson Dura-Vent
TM
is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or
TM
Vertical Terminal
Storm Collar
Flashing
Ceiling Firestop
Pipe Length
Pipe
Length
o
90 Elbow
Rigid Pipe
Adaptor (770-994)
alternate
Horizontal Termination
caps
Alternate Snorkel
Termination Cap
installation
Vinyl Siding
Standoff (Optional)
AstroCap XL
Termination Cap
(Part #946-623/P)
Wall Thimble
(Mandatory in all
Horizontal Terminations)
Pipe Length
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.
Direct Vent Pro, ICC Excel and Selkirk
®
Regency Horizon HZ54E-10 Gas Fireplace
|
21
Vent Guard - if required*
(Part #946-506/P)
|
21