Table of Contents

Advertisement

Regency Horizon ™ HZ40E
WARNING:
If the information in these instructions are not followed exactly,
a fi re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed
installer, service agency or the gas supplier.
Tested by:
918-984
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
Gas Fireplace
Installer: Please complete the details on the back cover
Installer
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
: Please complete the details on the back cover
Installation Manual
MODELS:
www.regency-fi re.com
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fi re department.
Owners &
HZ
40E
-NG Natural Gas
HZ
40E
-LP Propane
09/27/11

Advertisement

Table of Contents
loading

Summary of Contents for Regency Horizon HZ40E-NG

  • Page 1 Regency Horizon ™ HZ40E Owners & Installation Manual Gas Fireplace MODELS: -NG Natural Gas -LP Propane www.regency-fi re.com WARNING: FOR YOUR SAFETY If the information in these instructions are not followed exactly, What to do if you smell gas: a fi re or explosion may result causing property damage, Do not try to light any appliance personal injury or loss of life.
  • Page 2: Manufactured Mobile Home Requirements

    Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the Untied States, or the Standard for Installation in Mobile Homes, CAN/CSA Z240 MH, in Canada. Regency Horizon™ HZ40E Gas Fireplace...
  • Page 3 To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY ® . The HZ40E has been designed to provide you with all the warmth and charm of a fi replace at the fl ick of a switch.
  • Page 4: Table Of Contents

    WARRANTY Unit Installation with Horizontal Termination ....33 Unit Installation with Horizontal Termination ....34 unit installation with Vertical Termination .....35 4" x 6-5/8" venting ............35 The Warranty: Limited Lifetime ........67 High Elevation Gas Line Installation ......36 Regency Horizon™ HZ40E Gas Fireplace...
  • Page 5: Copy Of Safety Decal

    MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE. 4001172 Minimum Clearances to Combustibles / NATURAL GAS: Model HZ40E-NG APPAREIL FONCTIONNANT AU NATURAL GAS Degagement Minimum De Materiaux Combustibles CONCU POUR ETRE POELE: Mod le HZ40E-NG é Minimum supply pressure 5.0" WC/C.E. (1.25kPa)
  • Page 6: Requirements

    (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. Regency Horizon™ HZ40E Gas Fireplace...
  • Page 7 DIMENSIONS 49-5/16" 45-5/8" 18-5/16" 39-13/16" 1-7/16" 16-1/2" 36 4 " (1092mm) (972mm) (1238mm) (902mm) (914mm) Regency Horizon™ HZ40E Gas Fireplace...
  • Page 8: Installation

    fi replace. 9) Wear gloves and safety glasses for protection while doing required maintenance. 10) Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination. Regency Horizon™ HZ40E Gas Fireplace...
  • Page 9: Installation Checklist

    The kit may be used on either the left Before leaving this unit with the customer, the or right side. installer must ensure that the appliance is fi ring correctly and operation fully explained to customer. Regency Horizon™ HZ40E Gas Fireplace...
  • Page 10: Clearances

    Front to Back Wall (Maximum) Passing through wall/ G: From Floor 27" (686mm) Top of Fireplace Opening floor/ceiling - when 1-1/2" fi restop is used. Note: 0" No hearth required Installed Close Installed close to Floor to ceiling. Alcove Regency Horizon™ HZ40E Gas Fireplace...
  • Page 11: Mantel Clearances

    To Unit 27” Base Top of Fireplace Opening MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram: 5-11/16”(144mm) MANTEL LEG Non-Combustible 1.5" (38mm) 7-1/8” (181mm) Allowable mantel legp rojection 10” ( 203mm) 13”( 279mm) Regency Horizon™ HZ40E Gas Fireplace...
  • Page 12: Unit Assembly Prior To Installation

    3) The side/top nailing strips which are attached to this unit will also need to be adjusted. See Framing and fi nishing in this manual. Regency Horizon™ HZ40E Gas Fireplace...
  • Page 13: Framing Dimensions

    The nailing strips can be adjusted back up to 1” to allow for varying thicknesses in non-combustible material & wall fi nishes. Drywall or other facing Metal Stud (Header) Note: All other framing may Non-Combustible be of wood construction. Facing Metal Stud on edge Finished Floor Regency Horizon™ HZ40E Gas Fireplace...
  • Page 14: Non-Combustible Requirements

    6) Prime wall for a second time for proper adhesion of paint 7) Paint walls using a high quality paint which will withstand the high temperatures being emitted from this appliance. Non-combustible board MUST BE PRIMED. Regency Horizon™ HZ40E Gas Fireplace...
  • Page 15: Framing & Finishing

    1/2" required between faceplate + fi nished wall IMPORTANT: 1/2" gap required between faceplate and fi nished wall when Unit shown with inner door frame only using 4 pce. Faceplate (Part # 256-924, 256-926, 256-927) Regency Horizon™ HZ40E Gas Fireplace...
  • Page 16: Framing & Finishing

    0" (fl ush) Nailing Strip Flush w/unit Factory Set Unit NON-COMBUSTIBLE REQUIREMENTS Metal Stud (header) on edge 51-5/16" (1303mm) Metal Stud Metal Stud Non-combustible Material Non-combustible 10" (252mm) May be combustible (ie. 1/2” drywall) 5-11/16" (144mm) Regency Horizon™ HZ40E Gas Fireplace...
  • Page 17: Exterior Vent Termination Requirements

    * Clearance in accordance with local installation codes and the requirements of the gas supplier 3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly 3 feet (91cm) above - if within 10 feet (3m) horizontally Regency Horizon™ HZ40E Gas Fireplace...
  • Page 18: 4" X 6-5/8" Rigid Pipe

    Offset Support 46DVA-ES (N/A - FPI) 4DT-OS SV4SU Wall Thimble-Black 46DVA-WT 4DT-WT 4DWT 4DWT SV4RSM TE-4DE90 Wall Thimble Support/Ceiling Support 46DVA-DC SV4PF TE-4DE90B Firestop Spacer 46DVA-FS 4DT-FS 4DFSP 4DFS SV4BF Trim Plate-Black 4DT-TP 4DFPB 4DCP SV4LA Regency Horizon™ HZ40E Gas Fireplace...
  • Page 19 Note: Horizontal runs of vent must be level, or have a 1/4” rise for every 1 foot of run towards the termination. Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard. Regency Horizon™ HZ40E Gas Fireplace...
  • Page 20: Vent Restrictor Position

    4) Once the vent restrictor plate is in the required position, secure with screws. Set 0 Set 1 Set 2 Set 3 (Factory set) VENT RESTRICTOR VENT RESTRICTOR VENT RESTRICTOR VENT RESTRICTOR AT 2" AT 1-1/2" AT 1" AT 3" Regency Horizon™ HZ40E Gas Fireplace...
  • Page 21: Venting Introduction

    Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting of Set 0 to Set 1 if required. Note: For horizontal terminations the Regency Direct Vent Flex System may be used for installations with a maximum continuous vent length of up to 10 feet.
  • Page 22: Horizontal Terminations

    S.S. screws #8 x 1-1/2” drill point Notes: 1) Liner sections should be continuous without any joints or seams. 2) Only Flex pipe purchased from Regency ® may be used for Flex installations 3) Horizontal vent must be supported every 3 feet.
  • Page 23: Horizontal Terminations

    American Metal Products Ameri Vent Direct Vent, Security Secure Vent ® , ICC Excel, Selkirk Direct-Temp. AstroCap is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. Regency Horizon™ HZ40E Gas Fireplace...
  • Page 24: Rigid Pipe 4" X 6-5/8

    With the above options, maximum total pipe length if 37 feet with minimum of 6 feet total vertical and maximum 17 feet total horizontal. Please note minimum 1 foot between 90 elbows is required. Please note the minimum centerline for basic install shown above. Regency Horizon™ HZ40E Gas Fireplace...
  • Page 25 3' Max. 4' Min. 6' Max. Please note minimum 4' Max. 6' Min. 7' Max. 1 foot between 90 elbows is required. 5' Max. 8' Min. 8' Max. Restrictor Position - Set 0 (factory setting) Regency Horizon™ HZ40E Gas Fireplace...
  • Page 26 1 f o o t 6' Min. 5' Max. 10' Min. 8' Max. between 90 elbows 7' Min. 6' Max. 12' Min. 9' Max. is required. Restrictor Position - Set 0 (factory setting) Regency Horizon™ HZ40E Gas Fireplace...
  • Page 27: Vertical Terminations

    American Metal Products Ameri Vent Direct Vent, Security Secure Vent ® , ICC Excel, Selkirk Direct-Temp. AstroCap is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. Regency Horizon™ HZ40E Gas Fireplace...
  • Page 28: Venting Arrangement For Vertical Terminations

    Set 0 to Set 1 or Set 2 if required. Vent Restrictor on Set 2 Vent Restrictor on Set 1 Max. 10’ (3m)(centerline to centerline) Minimum length of pipe between elbows 12” (305mm) Regency Horizon™ HZ40E Gas Fireplace...
  • Page 29: Vertical Termination With Co-Linear Flex System

    46DVA-GK 3" Co-linear Adapter with fl ashing Outer Pipe with Kit# 946-563 Air Intake Pipe Length Co-Linear Flex Rigid Pipe Adapter Adapter # 510-994 with Kit# 946-563 45 Elbow Inner Pipe Adapter with Kit# 946-563 Regency Horizon™ HZ40E Gas Fireplace...
  • Page 30: Vertical Terminations

    6' Min. 6' Max. 6' Min. Restrictor Position - Set 0 (factory setting) Restrictor Position - Set 0 (factory setting) For additional vertical venting with 2 x 90 elbows, refer to "Rigid Pipe Venting Arrangements" Section. Regency Horizon™ HZ40E Gas Fireplace...
  • Page 31 Please note min. 1 foot 5' Min. 6' Max. 8' Min. between 90 elbows is 6' Min. 7' Max. 9' Min. required. 7' Min. 8' Max. 10' Min. Restrictor Position - Set 0 (factory setting) Regency Horizon™ HZ40E Gas Fireplace...
  • Page 32: Venting Arrangements - Vertical Terminations

    Set 2 Horizontal Distance (Feet) Horizontal Distance (Feet) Horizontal Distance (Feet) The shaded area in the diagrams show the allowable vertical terminations when using two- 3" co-linear aluminium fl ex and 4 x 6-5/8" rigid pipe. Regency Horizon™ HZ40E Gas Fireplace...
  • Page 33: Unit Installation With Horizontal Termination

    3 supplied screws (drilling pilot holes will make this easier). 4) Level the fi replace and fasten it to the framing Diagram 2 using nails or screws through the top and side nailing strips. Diagram 7 Diagram 1 Regency Horizon™ HZ40E Gas Fireplace...
  • Page 34: Unit Installation With Horizontal Termination

    fl ex pipe (10" (254mm) and slip it over the outer fl ue collar of the vent Outer Diameter) terminal at least 1-3/8"(35mm) and fasten with the 3 screws. Regency Horizon™ HZ40E Gas Fireplace...
  • Page 35: Unit Installation With Vertical Termination

    Note that for steep roof pitches, the vertical height must be increased. A poor draft, or down drafting can result from high wind conditions near big trees or adjoining roof lines, in these cases, increasing the vent height may solve the problem. Regency Horizon™ HZ40E Gas Fireplace...
  • Page 36: High Elevation Gas Line Installation

    6) When fi nished reading manometer, turn off the unit, disconnect the hose and tighten the screw (clockwise) with a 1/8" fl at screwdriver. Note: Screw should be snug, but do not over tighten. Regency Horizon™ HZ40E Gas Fireplace...
  • Page 37: Ac Power Adaptor Installation (For Surefi Re Systems)

    5) Neatly tuck any loose AC Power Adaptor wires neatly underneath / inside the appliance. Note: (keep wires away from the heat as much as possible). FCM - COM Regency Horizon™ HZ40E Gas Fireplace...
  • Page 38: Wiring Diagram

    Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Regency Horizon™ HZ40E Gas Fireplace...
  • Page 39: Profl Ame System Gt

    CAUTION: Label all wires prior to disconnection Caution: Ensure that the wires do not touch any when servicing controls. Wiring errors can cause hot surfaces and are away from sharp edges. improper and dangerous operation. Regency Horizon™ HZ40E Gas Fireplace...
  • Page 40: Profl Ame System Gtmf With Optional Fan

    Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Regency Horizon™ HZ40E Gas Fireplace...
  • Page 41: Optional Fan Wiring Diagram

    Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Regency Horizon™ HZ40E Gas Fireplace...
  • Page 42: Optional Remote Control

    **Important: Must also choose a 10 foot Profl ame GTMF wire harness in order to attach wire harness to receiver located on wall for this remote control. CAUTION Do not wire millivolt remote control wires to 120V wire. Regency Horizon™ HZ40E Gas Fireplace...
  • Page 43: Wall Mount On / Off Switch And Battery Compartment Installation And/Or Receiver Installation

    11. Using the two (2) screws provided secure the cover plate to the Receiver. Low Voltage Junction Box Optional Profl ame Receiver J-Box Receiver Slider Switch Wall Plate 10 ft. wire harness with 12 pin connector Diagram 1 Regency Horizon™ HZ40E Gas Fireplace...
  • Page 44 Note: Ensure switch is in OFF position prior to installing batteries. 7. Install battery compartment into junction box. 8. Using the two (2) screws provided, secure the sealed white cover plate. Wall switch ON/OFF Switch or optional wall thermostat Optional AC Adaptor Battery compartment Regency Horizon™ HZ40E Gas Fireplace...
  • Page 45: Gtmf Remote Installation

    (FCM) into the outlet in the unit - reinstall the panel with 4 screws from step 2. * Prior to removing burner - remove crystals, pebbles, spa stones and inner panels - if installed. 4) Proceed to Step 11. Regency Horizon™ HZ40E Gas Fireplace...
  • Page 46 7) Remove the left access plate by removing 8 screws - see locations below. Left side access 10) Install the fan control module (FCM) into the bracket as shown below. Regency Horizon™ HZ40E Gas Fireplace...
  • Page 47 FCM Wire 13) See Profl ame remote instructions for coding remote to receiver as well as operating instructions. 14) Reverse steps 2-1 for new installations. Reverse steps 8 - 1 for existing installations. Regency Horizon™ HZ40E Gas Fireplace...
  • Page 48: Optional Fan Installation

    IMPORTANT: These fans collect a lot of dust from within your home. Ensure you maintain these fan motors on a regular basis by vacuuming the fan blades and housing using a soft brush nozzle. Regency Horizon™ HZ40E Gas Fireplace...
  • Page 49: Optional Fan Installation - Into Existing Installations

    6) Remove the burner tray cover by lifting up and out as shown below. 10) Remove the left access plate by undoing the 8 screws - see locations below. * Prior to removing burner - remove crystals, pebbles, spa stones and inner panels - if installed. Regency Horizon™ HZ40E Gas Fireplace...
  • Page 50 11) To complete fan installation - follow steps 2- 7 on previous page. NOTE: The right access panel wasremoved to allow easier access to secure the right screw on the fan base. 12) Reverse steps 9-1 to complete install. Regency Horizon™ HZ40E Gas Fireplace...
  • Page 51: Inner Panel Installation

    fi rst. Use care not to scratch or mar the panel on the pilot 7) Reinstall glass door - reinstall faceplate. shield. Final Install 4) Install the left side panel - secure in position with the panel clip and two screws, as shown in the diagram below. Regency Horizon™ HZ40E Gas Fireplace...
  • Page 52: Glass Crystals Or Optional Ceramic Stones

    Optional Ceramic Spa Stones shown on burner. For units P33S, P33SE, L676S, U32S, U32SE, E33S only For units P33S,P33SE L676S, U32S, U32SE, E33S only Glass Crystals shown on Burner and Firebox Floor For Units HZI390E, HZI390EB, HZI540EB only Regency Horizon™ HZ40E Gas Fireplace...
  • Page 53: Optional Pebble / Crystal Installation

    Natural River Pebbles shown surrounding the a Horizon Burner River Pebbles shown surrounding a Sunrise Burner Glass Crystals shown surrounding the Burner Regency Horizon™ HZ40E Gas Fireplace...
  • Page 54: Glass Door Installation

    3) Install cover plates over each screw with 2 magnets each as shown below. Magnet Cover Plate Diagram 4 Diagram 1 Hook top of door onto top flange Flush Door Cover Plates Installed Diagram 5 Diagram 2 Regency Horizon™ HZ40E Gas Fireplace...
  • Page 55: Optional Mesh Glass Guard

    2) Using existing door frame screw, install lower mesh mounting brackets on left side and right side, as shown. Mesh mounting clips Lower mesh mounting brackets 5) Install faceplate - refer to faceplate installation instructions in manual. Regency Horizon™ HZ40E Gas Fireplace...
  • Page 56: Piece Faceplate Installation

    - up to 1/2". Important: 1/2" gap required between faceplate and fi nished wall when using part #256-924, 256-926, 256- 927 (4 pc. faceplate). +1/2" +1/4" Use fi rst notch in bracket Final Install for standard installation Regency Horizon™ HZ40E Gas Fireplace...
  • Page 57: Inner And Outer Door Frame Installation

    Inner door frame may be installed by itself, or with the outer door frame. The outer door frame cannot be installed by itself - if install- ing the outer door frame - the inner door frame must also be installed. 918-905a 08/24/11 Regency Horizon™ HZ40E Gas Fireplace...
  • Page 58: Operating Instructions

    fi lm will bake on and become very diffi cult to remove. Use a non-abrasive cleaner and DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT. Regency Horizon™ HZ40E Gas Fireplace...
  • Page 59: Copy Of Lighting Plate Instructions

    If service is to be performed - you must disconnect power to the unit, from the battery pack, refer to manual. Appuyez sur le bouton ON / OFF Si le service est effectuée, vous devez débrancher l'appareil, du bloc-piles, voir le manuel d'instruction pour plus de détails. DO NOT REMOVE THIS INSTRUCTION PLATE 918-628c Regency Horizon™ HZ40E Gas Fireplace...
  • Page 60: Maintenance Instructions

    & reinstalled in accordance with the appliance with the glass panels manufacturer's instructions. removed, cracked or broken. Replacement of the glass panels 8) Verify operation after servicing. should be done by a licensed or qualifi ed service person. Regency Horizon™ HZ40E Gas Fireplace...
  • Page 61: Valve Assembly Replacement

    10) Disconnect the inlet gas line and remove the valve assembly. panels - if installed. 11) Replace valve assembly and reverse steps. 7) Remove 3 screws on the burner to release it - locations shown below. Regency Horizon™ HZ40E Gas Fireplace...
  • Page 62: Parts List

    256-530 Burner Assembly LP c/w Cap HZ40E 256-574/P Valve Assembly HZ40E NG SIT 904-345 Orifi ce #53 LP 256-576/P Valve Assembly HZ40E NG SIT 904-593 Orifi ce #40 NG 910-157/P Fan Low Speed (Dual Blower) Regency Horizon™ HZ40E Gas Fireplace...
  • Page 63: Accessories

    Outer Door Frame Stainless 256-944 Inner Door Frame Black 256-946 Inner Door Frame Bold 256-947 Inner Door Frame Stainless 946-676 Copper Glass Crystals 946-672 Natural River Pebbles 946-673 White River Pebbles 946-674 Ceramic Spa Stones Regency Horizon™ HZ40E Gas Fireplace...
  • Page 64 NOTES Regency Horizon™ HZ40E Gas Fireplace...
  • Page 65 NOTES Regency Horizon™ HZ40E Gas Fireplace...
  • Page 66 NOTES Regency Horizon™ HZ40E Gas Fireplace...
  • Page 67: Warranty

    Conditions: Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at Regency's option, through an accredited distributor or agent provided that the defective part be returned to the distributor or agent Transportation Prepaid, if requested.
  • Page 68 Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Regency Horizon and SureFire are trademarks of FPI Fireplace Products International Ltd. © Copyright 2011 FPI Fireplace Products International Ltd. All rights reserved. Printed in Canada...

This manual is also suitable for:

Horizon hz40e-lpHorizon hz40e

Table of Contents