This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the remote control/thermostat will continue
to operate. However, a 120V A.C. power supply is needed for the fan/blower operation.
(Do not cut the ground terminal off under any circumstances.)
NOTE: Even if the fan is not purchased with the unit,we highly recommended bringing power to the receptacle box (provided with the unit) in case
the fan is installed at a later date. The AC adaptor is included with this appliance.
AC Adaptor

WirinG diaGraM

Proflame System
Configuration
Proflame System
Configuration
885 ON/OFF
886 GTMF
Illustrated wire diagram
Wire Diagram
SureFire™ Switch
0.584.907
Caution: Ensure that the wires do not touch any
hot surfaces and are away from sharp edges.
caution: Label all wires prior to disconnection
when servicing controls. Wiring errors can
cause improper and dangerous operation.
installation
0.885.001
note: either 4 AA batteries or AC adaptor must be
installed to operate the burner switch/Receiver.