Important: 120 Volt AC power is needed for the blower.
The receptacle box is installed on the left hand side of the unit and must
be wired by a qualifi ed electrician prior to fan assembly being installed.
The neutral (wider) slot of the polarized receptacle should be at the top.
1) Turn the unit off and allow it to cool down to room temperature.
2) Turn off the gas supply to the unit.
3) Remove the faceplate by lifting it up off the slots on the sides of the
fi rebox.
4) Remove the door frame overlay by swinging out 45
lift up and out.
42 |
Regency Horizon HZ54E-10 Gas Fireplace

OPTIONAL FAN INSTALLATION

from the bottom and
o
5) Remove the glass door.
a) Remove cover plates from over each screw by pulling away from 2
magnets each as shown below.
Cover Plate
Diagram 4
b) Remove the 3 screws shown below at the bottom of the glass
.
door
c) Swing the door out 45
from the bottom and lift up and out.
o
Steps 6 & 7 for NG units only:
6) Remove the burner tray by undoing the 2 screws in between the
bottom cover and burner on the fi rebox. Carefully lift the burner up and
out ensuring not to spill the glass crystals.
Aerial View of the inside of the unit shown.
7) Remove bottom cover by undoing 3 screws securing it to the fi rebox
base, lift up and out.
Aerial View of the inside of the unit shown.
Magnet