Optional Fan Installation - Regency Panorama P33E-NG11 Manual

Table of Contents

Advertisement

installation
|
56

Optional Fan Installation

120 Volt AC power is needed for the fan. The fan can be hard
wired if desired. The outlet should be installed in the recep-
tacle box on the left hand side by a qualified electrician. The
neutral (wider) slot of the polarized outlet should be at the top.
Unit must be grounded at all times. Do not cut the ground
terminal off under any circumstances.
1. Turn off electrical supply to unit.
2. Remove safety screen and faceplate if installed.
3. Turn the fan base on its side (with base facing forward) and
then slide the fan in towards the rear of the unit. Turn the fan
upright and slip it over the two mounting studs. Take care not
to damage the insulation on the fan base.
Ensure the fan blades do not rub against the valve tubing.
4
. Connect the power cord and fan ground wires to the ground
lug. Refer to wiring diagram.
5. Slide the thermodisc / cover assembly on to the bracket clip
on the underside of the firebox.
56 |
Regency
®
P33E-11 Zero Clearance Direct Vent Gas Fireplace
OPTIONAL FAN INSTALLATION
Thermodisc Clip
6. Install the Fan Control Module (FCM) on the base of the
unit to the left of the gas valve. Plug the FCM into the
outlet.
7. Plug in the fan power cord to the Fan Control Module into
the outlet marked "Fan". Plug the FCM-COM wire from the
remote control wiring harness into the location on the Fan
Control Module marked "COM". Turn the switch on the Fan
Control Module to the ON position. ON is to the left. The
"O" is the off position.
TO REMOVE THE FAN
1) Turn the power off.
2) Reverse the above instructions.
MAINTENANCE: The sealed bearings are lubricated so there
is no need to lubricate them further. Extra lubricant will cause
more lint and dust to build up causing the premature failure of
the bearings.
Regular cleaning and vacuuming of the fan area will add to the
life of the motor.
IMPORTANT:
THESE FANS COLLECT A LOT OF DUST FROM WITHIN
YOUR HOME. ENSURE YOU MAINTAIN THESE FAN
MOTORS ON A REGULAR BASIS BY VACUUMING THE
FAN BLADES AND THE HOUSING WITH A SOFT BRUSH
NOZZLE.